External Sequential Compression Device My-S039-a

Product ParametersTechnical parameters: 1. Normal working conditions: 1.1. Working environment: temperature 5ºC~40ºC; 1.2. Relative humidity: 10%~80%; 1.3. Atmospheric pressure: 86kPa~106kPa; 1.4. External power supply: working voltage: ~ 220V±10%; power frequency: 50Hz ±1Hz; 1.5. Input power: ≤60VA. 2. Rotary knob and LCD touch screen , easy to operate; 3.★With step pressure setting function 4. Time setting: continuous operation or setting function time range 0~99min, each step 1min; 5. The adjustment range of the inflation interval time is 0-90seconds,each step 5seconds; 6. The pressure holding time is adjustable from 0-12seconds; 7.★Treatment mode: 4 inflatable modes; Mode A: Distal-to-proximal one-by-one (chamber) conventional inflation mode Mode B: Progressive (chamber-by-chamber) inflation pattern from distal to proximal Mode C: Progressive (chamber-by-chamber) inflation pattern from proximal to distal Mode D: Regular inflation pattern by (chamber) from proximal to distal 8. Pressure indication: The therapeutic apparatus has a pressure indication to indicate the therapeutic pressure generated by the therapeutic apparatus in the airbag under the current treatment procedure; 9. ★Pressure adjustment: the airbag pressure adjustment range is 0~200 mmHg, and the set adjustment step is 5 mmHg each; 10. The ultimate pressure is less than or equal to 300 mmHg, and the duration of exceeding 15 mmHg is not more than 3 minutes;11. Overpressure protection: The therapy device has an overpressure protection function; 12. ★Emergency stop switch: The therapy device provides an individual emergency stop switch in addition to the power supply and function switch, which can stop the treatment program at any time; 13. Manual pressure release: The therapy device provides manual release pressure function for the patient under various conditions; 14. Air tightness: the airbag and the connecting pipeline should have good air tightness, keep it for 1 min under the maximum output pressure, and the pressure drop should not be more than 10%; 15. Connection: The connecting pipeline should have a device or mark to prevent wrong connection; 16. ★The therapy instrument has the function of setting therapy parameters, which can select the therapy mode, and airbag type, set the therapy pressure and therapy time of each chamber; 17. The therapy device has a therapy parameter display function, which can display the currently set therapy parameters, as well as the current inflation pressure, remaining therapy time; 18. ★Working noise: The noise of the therapeutic apparatus during normal operation should not be greater than 45dB (A)Detailed Photos      /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1