Alucoone Exterior Cladding Aluminium Composite Panel

 Alucoone B1 class fireproof aluminum composite panel, it contains 60% flame retardant, the main ingredients are aluminum oxide and magnesium oxide ; When B1 grade panels are put on fire, it can be burned on fire after 5 minutes, and when the fire leave the panels, the fire on the panels will extinguish after 10 seconds.alucoone B1 grade fireproof ...   Colors & SurfacesThe colors of fireproof aluminum composite panel ,we can make more than 100 kinds, RAL color card, Pantone color or customer supplied the color.The surface can be made PE coating, PVDF coating, Brushed coating, Mirror coating, FEVE coating, NANO coating and some special coating some like: Wood, Marble, Spectrum, Embossed etc.   Product RangesSurface coatingPVDF marble coatingPolyester marble coatingAluminum alloyAA1100 seriesAA1100 seriesAluminum skin0.25mm,0.30mm,0.35mm,0.40mm,0.45mm,0.50mm0.08mm,0.10mm,0.12mm, 0.15mm,0.21mm,0.25mm,0.30mm,0.35mm,0.40mm,0.45mm,0.50mmPanel thickness3mm ,4mm,5mm,6mm3mm, 4mm,5mm,6mm,12mmPanel width1220mm 1250mm 1500mm1220mm,1250mm,1500mmPanel length2440mm,3050mm,5000mm2440mm,3050mm,5000mmBacking coatingPrimer coatingPrimer coatingGlossy20%-40%40%-70%Dimensional tolerance:Panel width: ±2mm        Panel length:±3mm    Panel thickness:±0.2mm    Panel diagonal: ≤5mmAluminum sheet thickness: ±0.01mmProduct propertiesRaw material:Base material: High strength aluminum alloy sheetPE core material: Non-combustion mineral material  B1 gradeSurface coating: PVDF, Polyester, FEVE, NANO -PVDF, SpectraBack coating: Primer coatingProduct Properties:*Excellent fire resistant, hardly flammable*Excellent sound, heat insulation*Superior impact & peel strength*Excellent surface flatness & smoothness*Light weight & easy to maintainAPPLICATIONS1. Wall curtain, Cladding and Facade2. Interior decoration and furniture3. Exterior renovation for old buildings4. Subway and airports5. Industry plants and materials,6. Vehicle and boat materials Technical DataThe contrast of fire-resist performance in different countries                             Standard        China   Germany   U.S.A   France   U.K       Japan     Russia      Burning Degree| GB/T8627  DIN 4102  ASTM E84   BS 476   NFF 16-101  JIS K6911  30244-94     Few            A       A1,A2      NC     O      M0       1        T1----------------------------------------------------------------------------------------------------------------------Minor          B1       B1         A      1     M1,M2     2        T2----------------------------------------------------------------------------------------------------------------------Normal         B2       B2         B,C   2,3       M3      3        T4----------------------------------------------------------------------------------------------------------------------Serious         B3       B2                4      M4, M5     -        -                                                                               The level and combustion properties of names                                                                                   Degree               Item                  Degree                Item             A                  None-combustion                 B2                Combustion------------------------------------------------------------------------------------------------------------------------------------------ B1                 Hard-combustion                  B3                Combustion----------------------------------------------------------------------------------------------------------------------------------------- Degree              Material                  The combustion performance indicators----------------------------------------------------------------------------------------------------------------------------------------- None-combustion     Class A Material       According to GB/t8625 test, the average length of the remaining                                         ≤35cm(Including any residual specimen ≥20cm) for each                                         test and average flue gas temperature peak ≤150 ºC,no                                           Specimen back burner the scene; According to GB/8627 test,                                         Their smoke density levels (SDR) ≤ 15;                                         According to GB/T14002 and GB/T14403 test, its calorific                                         Value ≤16.8M/                                    Toxicity materials combustion flu gas of the entire                                   non-lethal concentration of ≥ 25mg/L----------------------------------------------------------------------------------------------------------------------Hard-combustion     Class B1 Material       According to GB/T8626 test, its combustion properties should be                                         met GB/T8626,and does not allow any dropping of combustion                                         Burn the filter paper;