New Style AC to DC 100W Industrial DIN Rail Single Output Switching Power Supply

Product DescriptionMDR-10,20,40,60,100 series is a 10,20,40,60,100W single output closed power supply, with a 30mm low profile design, using 85-264VAC full range AC input series to provide 5V,12V,15V,24V,36V and 48V output.ln addition to efficiency as high as 91.5%,the metal mesh enclosure is designed to enhance the heat dissipation capability so that the MDR-10,20,40,60,100 operates in the temperature range from -30ºC to +70ºC without fans. It provides ultra-low no-load power consumption (less than 0.3W), which makes the terminal system easy to meet the intern-ational energy requirements. MDR-10,20,40,60,100 has complete protection function and anti-5G vibration capability;It conforms to EN 60950-1,EN 60335-1,EN 61558-1/-2-16 GB4943 international saety regulations; MDR-10,20,40,60,100 series provides a cost-effective solution for various industrial applications.Product Parameters  MDR-10,20 Rail type switch power supplyTypeTechnical indicatorsOutputDC voltage5V12V15V24VRipple and noise84%Shock current110VAC 35A.220VAC 70AProtection characteristicsShort circuit protection105%-150% Type:protection mode: burp mode automatic recovery after the abnormal condition is liftedOver voltage protectionOutput voltage is 135%>, close the output.When the abnormal condition is lifted,it will resume automaticallyEnvironmental scienceWorking temperature and humidity-20ºC~+70ºC;20%~90RHStorage temperature and humidity-40ºC~+85ºC; 10%~95RHSecurityPressure resistanceInput-output :3KVACIsolation resistanceInput-output and input-shell, output-shell:500VDC/100mΩOtherSize22.5*90*100mm(L*W*H)Net weight/gross weight170/185gRemarks(1) Measurement of ripple and noise: Using a 12"twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal,the measurement is carried out at 20MHz bandwidth.(2)Efficiency is tested at the input voltage of 230VAC, rated load and 25ºC ambient temperature.Accuracy:including setting error,linear adjustment rate and load adjustmient rate.Test method of linear adjustment rate: testing from low voltage to high voltage at rated loadLoad adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the startup time.When the altitude is above 2000 meters, the operating temperature should be lowered by 5 /1000.  TypeMDR-10DC voltage5V12V15V24VRated current2A0.84A0.67A0.42ARated power10W10W10W10WVoltage precision±5%±3%±3%±2%Working current0.33A/110VAC 0.21A/230VAC  TypeMDR-20DC voltage5V12V15V24VRated current3A1.67A1.34A1ARated power15W20W20W24WVoltage precision±2%±1%±1%±1%Working current0.33A/110VAC 0.21A/230VAC  MDR-40,60 Rail type switch power supplyTypeTechnical indicatorsOutputDC voltage5V12V24V48VRipple and noise88%Shock current110VAC 35A.220VAC 70AProtection characteristicsShort circuit protection105%-150% Type:protection mode: burp mode automatic recovery after the abnormal condition is liftedOver voltage protectionOutput voltage is 135%>, close the output.When the abnormal condition is lifted,it will resume automaticallyEnvironmental scienceWorking temperature and humidity-20ºC~+70ºC;20%~90RHStorage temperature and humidity-40ºC~+85ºC; 10%~95RHSecurityPressure resistanceInput-output :3KVAC lasted for 1 minuteIsolation resistanceInput-output and input-shell, output-shell:500VDC /100mΩOtherSize40*90*100mm(L*W*H)Net weight/gross weight300/325gRemarks(1)Measurement of ripple and noise: Using a 12"twisted-pair line with a capacitor of 0.1uF and 47uF in parallel at the terminal,the measurement is carried out at 20MHz bandwidth.(2)Efficiency is tested at the input voltage of 230VAC, rated load and 25ºC ambient temperature.Accuracy:including setting error,linear adjustment rate and load adjustmient rate.Test method of linear adjustment rate: testing from low voltage to high voltage at rated loadLoad adjustment rate test method: from 0%-100% rated load.The start-up time is measured in the cold start state, and the fast frequent switch machine may increase the startup time.When the altitude is above 2000 meters, the operating temperature should be lowered by 5/1000.  TypeMDR-40DC voltage5V12V24V48VRated current6A3.3A1.7A0.83ARated power30W40W40.8W39.8WVoltage precision±2%±1%±1%±1%Working current1.1A/110VAC 0.7A/220VAC  TypeMDR-60DC voltage5V12V24V48VRated current10A5A2.5A1.25ARated power50W60W60W60WVoltage precision±2%±1%±1%±1%Working current1.8A/110VAC 1A/230VAC  MDR-100 Rail type switch power supplyTypeTechnical indicatorsOutputDC voltage12V24V48VRated current7.5A4A2ARated power90W96W96WRipple noise87%Working current85°when close the output temperature drop after power supply recovery after restartEnvironmental scienceWorking temperature and humidity-20ºC-+70ºC;20%-90RHStorage temperature, humidity-40ºC-+85ºC;10%-95RHSecurityPressure resistanceInput-output:3kvac lasted for 1 minutelsolation resistanceInput-output and input-shell, output-shell:500 VDC/100mΩOtherSize55*90*100mmNet weight/gross weight420/