Kemapower Wholesale Price Wi-Fi GPRS Kit Inbuilt MPPT 48V80A Solar Controller 5kw off Grid Hybrid High Frequency Solar Inverter

PRODUCT DESCRIPTIONKEY FEATURES1. Off grid hybrid solar inverter SUB 1.5/3/3.2/5/5.5KW ,PF=12. 3 in 1 design , Inverter + MPPT controller + AC Charger3. Solar,Grid and Battery Energy complement each other,priority selectable 4. Working without battery during daytime 5. High efficiency sine wave output,Minimal self-consumption6. Wide MPPT range 120Vdc--450Vdc, 80 or 100A adjustable7. Intelligent 3 stage AC battery charger,60 or 80A adjustable TECHNICAL SPECIFICATIONS  ITEMModelN-SUB1500N-SUB3000N-SUB3500N-SUB5000N-SUB5500N-SUB5000PINPUTRATED POWER1.5KW3KW3.5KW5KW5.5KW5KWVoltage230 VACSelectable Voltage Range 170-280 VAC (For Personal Computers)90-280 VAC (For Home Appliances)Frequency Range50 Hz/60 Hz (Auto sensing)OUTPUTVoltage230VAC ± 5%(Bat Mode)Surge Power2 times Rated power for 5 secondsOverload Protection5s@≥150% load; 10s@110%~150% loadEfficiency,PV to INV.97% (Peak)Efficiency,Battery to INV.94%(Peak)Transfer Time10 ms (For Personal Computers) ; 20 ms (For Home Appliances)Battery typeAGM/Flooded/user defined , Lithium ( need to mention when needed )BATTERY & AC CHARGERBattery Voltage24 VDC24 VDC24 VDC48 VDC48 VDC48 VDCFloating Charge Voltage27 VDC27 VDC27 VDC54 VDC54 VDC54 VDCOvercharge Protection33 VDC33 VDC33 VDC63 VDC63 VDC63 VDCCharge Current (Max)60A80 A80A80 A80A80 ASOLAR CHARGERPV Array Power (Max)2000W4000W5KW5000W6KW5000WMPPT Range120 ~ 450 VDCPV Array VOC (Max)500 VDCCharging Current (Max)80A, AC+Solar adjustable80A, AC+Solar adjustableMax100A AC+Solar80A, AC+Solar adjustableMax100A AC+Solar80A, AC+Solar adjustableEfficiency (Max)0.98DisplayLEDLine Mode or bat Mode, Charging status ,FaultLCDVac HZ, Charge Amp W, PV VDC Amp W , Load % VA W Amp ,bat % VDC ,,setup , Fault code, working mode,Setup/Adjust parameterSolar power /utility power/Battery priority, united Charge Current , AC Charge Amp, AC input range, VAC HZ, Bat VDC back to utility power, BAT VDC back to Bat Mode, Charge Source select ,Alarm on off , overload bypass, Bulk/ Floating Charge VDC, Bat Low Cut VDC ,  equalization Charge VDC / mins / days,Output working Modeutility power prioritydefault. Utility power priority, Solar and battery as backup when utility power not available Solar priority(SUB Mode)solar power priority, utility power supplement to load when solar power is not enough , utility not available, battery supplement to load. Working on daytime while No BatSBU prioritySolar power priority, When Solar power is not enough,battery to supplement.when battery power is not enough , utility power to load. Working on daytime while No Bat Product sizeL*W*H448*295*105mmNet Weight (kgs)Kg8.599101010Carton sizeL*W*H590*390*208mmCarton weightKg11111111.811.811.8/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1