3600W AC DC Switching Power Supply Telecom Rectifier

3600W AC DC Switching Power Supply Telecom RectifierProduct introduction:SPS series systems are compact and intelligent power system with capacity from 30A to 250A, containing rectifier modules, controller module, AC connection and DC connection. In addtion, easy installation to compact size add to the success of the system Product features:1.  19" 1U, 3U, 4U, 5U, 6U sub-rack, easy to be embedded into all standard kinds of telecom equipment;2.  System capacity from 30A to 250A;3.  PFC technique features the system high efficiency, energy-saving and up to 0.99 power factor;4.  Intelligent fan-cooling technique brings good cooling performance, low failure rate and high reliablity;5.  Fast on-line expansion of rectifier modules enabled by hot-swap;6.  N+1 rectifier module redundancy.Specifications for  48V Rectifier SystemModelSPS30-48  /MR4815SPS60-48    /CR4830SPS90-48    /CR4830 SPS120-48  /CR4830 SPS200-48  /SR4850 1U SPS210-48  /CR4830 SPS250-48  /SR4850 2URated Output Current30A60A90A120A200A210A250ARated Output Voltage53.5Vdc (42-58 Vdc)Output Power1740W3.6KW5.4KW7.2KW11.6KW12.6KW15KWAC InputAC Input Voltage Range176~300Vac, 1phase/3wire (@ full load)220/230vac 1 ph tolerances: 85~300vac 323~480vac 3ph tolerances: 208~520vacAC Input Frequency45Hz ~65HzAC input Power Factor≥0.99AC transfer Efficiency≥91%≥92%AC Input Lightening Protection NA 1*50A/2P  ClassC SPD1*50A/2P  ClassC SPD1*50A/2P  ClassC SPD1*50A/2P  ClassC SPD1*50A/2P  ClassC SPDDC Output Output Voltage Range42~58 VdcCurrent Share±5%Load Regulation≤0.5%Voltage Regulation≤0.1%EnvironmentOperating Temperature(-20 to 50°C) (Rectifier Temp Range: -45°C to 75°C)Relative Humidity5%~95% RH, No CondensationConfigurationRectifier Module2*MR48152*CR48303*CR48304*CR48304*SR48507*CR48305*SR4850Controller1*CAS-03D1*CAS-03D1*CAS-03D1*CAS-03D1*CAS-03D1*CAS-03D1*CAS-03DDC Distribution1*30A1*60A4*32A/1P      4*16A/1P (customizable)2*63A/1P 2*32A/1P2*16A/1P (customizable)2*125A/1P (customizable)2*125A/1P (customizable)CustomizableBattery Breaker1*30A/2*63A/1P or 1*100A/1P2*100A/1P 2*125A/1P2*125A/1P2*125A/1PAlarm Relay4pcs 4pcs 4pcs 4pcs 4pcs4pcs4pcsOthersStandardUL60950/EN60950, EN55022, RoHSCommunication PortSNMP, RS232/RS485, Dry contactSubrack Dimension (W*D*H) mm482*290*44(1U)482*290*44 (1U)482*330*132 (3U)482*330*176 (4U)482*330*222(5U)482*330*266(6U)OptionalWall-mountedWall-mountedDC Lightning Protection 2nd LVD, DC Lightning Protection2nd LVD, DC Lightning Protection2nd LVD, DC Lightning Protection2nd LVD;DC Lightning Protection  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1