Nader Miniature Circuit Breaker Ndb1-63 1A-63A AC400/415V (2P/3P/4P) 20, 000 Times Mechanical Life

Nader Miniature Circuit Breaker NDB1-63 1A-63AMain technical parameters Electrical parameters Number of Poles1P, 1P+N, 2P, 3P, 3P+N, 4P Rated working VoltageAC230/240/400/415V(1P);AC230/240V(1P+N);AC400/415V(2P,3P,3P+N,4P); DC60/80V(1P,2P)Rated Current1A,2A,3A,4A,5A,6A, 10A, 16A,20A,25A,32A,40A,50A,63A Rated Insulation Voltage500V Rated Frequency50/60HzRated Impulse Withstand Voltage4kV Breaking Capacity6kAInstantaneous Tripping CharacteristicB.C.D  Mechanical Life20000 times Electrical Life10000 timesProtection DegreeIP20 Rated current1A~63A Product certificationCCC,CE,TUV Ambient temperature-40ºC~+70ºC Stored ambient temperature-40ºC~+80ºC Heat and humidity resistanceThe relative air humidity ≤95% at the temperature of +55ºC Altitude≤2000mPollution degree3Hscode8537109090Application 1.Short -circuit protection 2.Over-load protection 3.Isolation NDB1-63 dedicated to the low voltage power distribution system of industrial, buildings, energy communications and infrastructure.Isolation function Practical breaking instructions View window within the green identification said contact in the off position Protection Degree IP20 Wire Feeding Mode Lines in for both up and down ends Use Category A Mounting Class II,IIITripping characteristic B type curve Protection of short circuit current small load Rated current:1A~63A Tripping characteristic:The instantaneous tripping range 3In~5In C type curve Protect normal load and distribution wire cable Rated current:1A~63A Tripping characteristic:The instantaneous tripping range 5In~10In D type curve Protect starting current big impact load(Such as motor, transformer) Rated current:1A~63A Tripping characteristic:The instantaneous tripping rang 10In~14InProduct certification and implementation of national standardsProduct certification:CCC,CE,TUV Conform to national standards:GB/T10963.1 ,IEC 60898-1Environmental requirements:RoHS 5,Normal Working conditions Ambient temperature:-40ºC~+70ºC Stored ambient temperature:-40ºC~+80ºC Heat and humidity resistance:The relative air humidity ≤95% at the temperature of +55ºC Altitude:≤2000m, if you want to apply it more than 2000m, you must refer to Miniature Circuit Breaker's reduced capacity table. Also you can refer to GB/T20645 the technological requirement of the low-voltage electrical equipment when it is used on high altitude. Pollution degree: 3Free from obvious vibration or shockInstallation method Modular construction,can be installed in TH35mm * 7.5 standard guide rail. 9.Connect line requirements The wire capacity: 1mm²~25mm²conducting wire Terminal screw: M5; Maximum ultimate torque : 2.0N.m10.Packaging and storage Quantity(1P product:12PCS/box,1PN/2P product:6PCS/box,3P product:4 PCS/box,3PN/4P product: 3PCS/box),Packing boxes of products should be stored in the air circulation and relative humidity is not more than 80% and the temperature is not higher than + 80 ºC,Not less than - 40 ºC in the air around without acid, alkali or other corrosive gases stored in the warehouse. In the above conditions, the storage period since the production date not more than three years.11.Accessory list and installation OF1 Auxiliary Contact Be installed to the left side of NDB1-63 to indicate the t ripping status of the breaker. SD1 Alarm Contact Be installed to the left side of NDB1-63 to indicate the fault tripping status of the breaker. MX+OF1 Shunt Release Be installed to the left side of NDB1-63,remotely controls the breaker opening and indicates the breaker tripping statusGQ1A Over&Under Voltage Tripping Device Be installed to the left side of NDB1-63,used for circuit of work voltage less than AV230V,which has defensive function such as over-voltage protection(G1A), 3P 3PN, 4P File No.:NDT2930143 Version:3 Page 8 of 8 low-voltage protection(Q1A),over&low-voltage protection(GQ1A),at the same time,no-tripping when power down; FF1 Double Auxiliary Contact Be installed to the left side of NDB1-63 to indicate the tripping status of the breaker FS1 Auxiliary and Alarm Contact Be installed to the left side of NDB1-63 to indicate the fault tripping status of the breaker. NDB1LE-63 residual current operated protective module Be installed on the right of NDB1-63 miniature circuit breaker, is applied to protect direct or indirect earth leakage faults. Notices 1.The user should responsible for the quality problem caused by taking the products apart or adjust the tripping parameters without permission.2.Touch the uninsulated bare part is not allowed when breaker is energized state. 3.Make sure reliable connection to prevent the abnormal heating of terminals. That can cause fault operation of breakers or terminal damage.4.Please remove the cover before installation, details please refer to Product Specification.     Wuhan Unique Mechanical and Electrical Equipment Co.,Ltd, base in Wuhan, China and have warehouse in Shenzhen and Shanghai, and agent in HongKong. We engaged to 5G network base designation and construction since the year of 2011, aft