Main Technical Parameter of Pin Composite Insulator  Design codeRated Voltage(KV)Ratedmechanicalstretch load(kn)Structure Height(mm)Minimumarcingdistance (mm)Minimum nominalcreepage distance(mm)Diameterof shed D(mm)Lightning impulsewithstand voltage[peak]≥(KV))Power frequencywithstand voltage(wet)≥(KV)FPQ-10/4T20104215125280148/1187542FPQ4-10/5T20105250165460148/11810542FPS-105/51052501803809010542     Main Technical Parameter of Suspension Composite Insulator  Design codeRated Voltage(KV)Ratedmechanicalstretch load(kn)Structure Height(mm)Minimumarcingdistance (mm)Minimum nominalcreepage distance(mm)Lightning impulsewithstand voltage[peak]≥(KV))Power frequencywithstand voltage(wet)≥(KV)Structure ofconnected marksFXBW4-10/701070400200480754216FXBW4-10/10010100450200480754216FXBW4-35/70357065045013202309516FXBW4-35/1003510072052016002309516FXBW4-66706670900710214041018516FXBW4-66/10066100940710214041018516FXBW4-110/10011010012401000331555023016FXBW4-145/12014512014801240412372535516FXBW4-220/100220100224019006300100093516FXBW4-220/160220160224019006300100093516FXBW4-330/160330160299026009075142557016FXBW-12/7012703901804601054216FXBW-15/7015704452256201054216FXBW-24/7024704502356351506516FXBW-24/7024704502656431506516FXBW-28/70287056038012502309516FXBW-33/70337056038011302309516FXBW-35/7035705503908502309516FXBW-36/70367058038012502309516FPQ2-24/42443101806451506516FPQ2-36/536562046011602309516   Main Technical Parameter of Post Composite Insulator  Design codeRated Voltage(KV)Ratedmechanicalstretch load(kn)Structure Height(mm)Minimumarcingdistance (mm)Minimum nominalcreepage distance(mm)Diameterof shed D(mm)Lightning impulsewithstand voltage[peak]≥(KV))Power frequencywithstand voltage(wet)≥(KV)FZSW-10/4104215125290100/907542FZSW-20/820840032075014215065FZSW-35/6356450360946148/11818595FZSW-66/66667606301886160/130410185FZSW-66/86687606302010220/190410185FZSW-110/1011010122010803530220/190500230FZSW-220/1022010244022007060220/1901000395  Main Technical Parameter of Composite Insulator for electric railway  Design codeRated Voltage(KV)Ratedmechanicalstretch load(kn)Structure Height(mm)Minimum nominalcreepage distance(mm)Lightning impulsewithstand voltage[peak]≥(KV))Power frequencywithstand voltage(wet)≥(KV)Structure ofconnected marksFQX1-2525606501400270130aaFQX2-2525208401400270130bbFQX3-25*25209301400270130bbFQX3-25*25207601400270130acFQX4-2525208061400270130ghFQX5-2525606451400270130afFQE3-25*25606401400270130ffFQE4-25*25208361400270130gcFQE5-25*25206951400270130deFQE5-2525206951400270130giMain Technical Parameter of Cross-arm Composite Insulator  Design codeCentral distancebetween channeland installation holeMin.Electric arcdistance(mm)Min nominalcreepagedistance(mm)Installation holediameter(mm)Rated bentwithstandload(KN)1 min powerfrequency wetwithstandvoltage(KN)Full wave lightningimpulse withstandwoltage(peak value)(KV)FSW3-10/2.5390274362182.545165FSW3-10/5400280410185.050185FSW3-35/56204901060225.0100265FSW3-66/108907351815236.0185410FSW3-100/101240107031802410230550Compostie InsulatorApplicationThe composite insulator line of XINNENG includes line insulators comprised of line rod, line post, traction line type and line spacer, station insulators comprised of outdoor solid core, indoor solid core type, post and tension hollow post and tension rod, insulatig bushing comprised of oil impregnated paper condenser wall bushing and dry type condenser wall bushing. Moreover, shed booster for station insulation, feeding rod for locomotive and dry type polymer current transformer are also available. The shed housing polymer for XINNENG composite insulator is prepared using specific composition mixing developed by XINNENG experts for years, contributing the highest grade of tracking and corrosion resistance in conformance with IEC standard, which shows no apparent degradation after artificial accelerate ageing for 1000h and natural exposure test for 15 years. The XINNENG insulator are manufactured with unique one-piece injection molding technique, excluding possibility of interface feakdown. Amain frouble which may destroy the normal operation of insulators. The unique gluing connection of line rod insulator with metal getting keeps FRP rod intact, providing the highest reliability of insulator in respect of its mechanical performance with practically no degradation even in environment of high temperature or severe cold. The composite insulator, characteristic of small size, light weight, high mechanical strength, shatter-free, easy handling, well shock-resistance, pollution-resistance and minor maintenance, grows fast as a new generation of insulator. Insulator with specific parameters other than those listed hereafter is required by customer, it can be supplied by technical agreement. If any insulator of other app;ication is needed, XINNENG is willing to proceed cooperative development to meet utmost the customer demand. Normal service conditionsa) Ambient air temperature within the range of -40ºC to +50ºC. b