M1-100L/4300 4 Pole 100A MCCB Moulded Case Circuit Breaker

 M1 circuit breaker MCCB  Product Description :                                                                                                                                                                            M1 series of moulded case circuit breaker is one of our new type products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 660V and used for circuit of A.C.50Hz, rated operating voltage AC 380V(or below). Rated operating current up to 1250A for infrequency over and shtarting of  the motors. Equipement with the pritection devices for over current, short circuit and undervoltage.Standard  IEC/EN60497-2 and GB14048.2                                   Basic Specification and Main ParametersModel:         M1 Breaking capacity of limiting:       L- Standard, M- middle, H-high Operation mode:    Blank: direct operate with handle                                                                                                                  P:         motor-drive operation                                                                             Z:      operation with rotary  Application  :     no code for distribution breakers                                                                                                           2-  motor protection circuit breakers Pole:    both 3P and 4P are available.  There are four types for neutral pole (N pole) of 4P                        A type: it doesn't mount overcurrent tripper, and N pole always switches on, it can not                                be on and off together with other 3 poles;                                                                                                                         B type:    it doesn't mount overcurrent tripper. It can be on and off together with the                                                other 3 poles  (On fist, then off)                                                                                                                                             C type:     mount overcurrent tripping component, it can be on and off                                                                          together with  other 3 poles (On fist, then off);                                                                                                 D types:  mount overcurrent tripping component, and N pole always                                                                           switches on, it  can not be on and off together with other 3 poles Accessories: will be available as requierment. Model No.Frame current (A)Rated current(A)Rated working voltage(V)Rated insulating voltage(V)Rated limit breaking capacity(KA)Rated operating breaking capacity(KA)Pole No.Arcing distance mm400V/690V400V/690VHYCM1-  63L636,10,16,20,25,32 ,40,50,6340050025*12.5*3≤50HYCM1-63M6350*25*3.4HYCM1-100L10016,20,25,32,40,50,  63,80,10069080035/817.5/43≤50HYCM1-100M10050/1025/52,3,4HYCM1- 100H10085/2042.5/103HYCM1-225L225100,125,160,180,200,22569080035/817.5/43≤50HYCM1-225M22550/1025/22,3,4HYCM1-225H22585/2042.5/103HYCM1-400L400225,250,315,350,40069080050/1025/53,4≤100HYCM1-400M40065/1032.5/53HYCM1-400H400100/12050/103HYCM1-630L630400,500,63069080050/1025/53,4≤100HYM1-630M63065/1032.5/53HYM1-630H630100/2050/103HYM1-800M800630,700,80069080075*37.5*3≤100HYM1-800H800100*50*3HYM1-1250M1250700,800,1000,125069080080*40*3≤100 Note: * is the testing parameter when 400V, 6A has no thermal release   /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1