AC50Hz 60Hz Earth Leak 25A Mini Electric Circuit Breaker

Basic Info.Model NO.HPRS485Breaking CapacityLow Voltage Circuit BreakersOperationElectric TypeSpeedNormal Type Circuit BreakerArc-extinguishing MediumAirInstallationInsertStructureMCBPoles Number4TypeCircuit BreakerFunctionConventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent ProtectionCertificationISO9001-2000, CERated Voltage220V-400VRated Current6A/10A/16A/20A/25A/32A/40A/50A/63A/80A/100A/125AMechanical LifeMore Than 15000 TimesTrademarkHOPTransport PackageCarton PackingOriginSichuan ChinaProduct DescriptionProducts DescriptionHOPDB series RS485 smart circuit breaker, suitable for AC 50HZ/60HZ, rated voltage 230V to 400V, rated current to 125A.Function 1. Remote opening and closingCommunication Interface:RS485/ Moubus-RTU; 2. Overload protection  3. Short circuit protection  4. Overvoltage protection  5. Loss of pressure protection  6. Undervoltage protection    Product ParamentersRated voltage Ue1P+N/2P AC230V/50HZ/60HZ   3P+N/4P AC400V/50HZ/60HZNumber of poles1P+N/2P/3P+N/4PRated current In6A/10A/16A/20A/25A/32A/40A/50A/63A/80A/100A/125ATrip typeC/D Breaking capacity6kA/10kAElectrical life≥ 6000 timesMechanical life≥ 15000 timesRated impulse withstand voltage (Uimp)≥ 6KVDielectric strength2000VAutomatic closing time tc≤ 3sOperating temperatureOperating environment temperature -40ºC-70ºC; average no more than +35ºC within 24 hoursrelative humidityThe relative humidity does not exceed 50% when the maximum temperature is +40ºC, and the relative humidity does not exceed 90% when the average minimum temperature of the wettest month does not exceed +20ºCProtection levelIP20 CertificationsCE-EMC CE-LVD ROHS ISO14001 ISO9001 OHSAS180001Our FactoryFAQQ: Do you have APP for the energy meter?A: Since different areas' clients have different using habit, so APP is always customized for clients according to the developing instructions clients give.Q: Can the smart energy meter support wireless communication?A: Yes, our wall mounted energy meter is with built-in communication modem; and din rail energy meter need to be connected to an external data collector/DTU with communication modem.Q: Can you put our logo on the smart energy meter, DTU and software?A: Yes, we can put your logo on the meter, data collector(concentrator) and system software.Q: Can I confirm whether the communication is successful through the indicators light on the meter?A: Yes. From the two status indicators of the meter, you can identify the communication status of the meter network; When the green light flashes, the communication module works normally.Q: If the load of 100A needs to be switched off, can you achieve it with your electricity meter?A: 100A load can be pulled, but the circuit breaker (outer pull) needs to be configured, and the 60A meter can be pulled by the internal relay breaker.