IP20 3 Phase Three Phase Online UPS 10kVA 15kVA 20kVA 30kVA 40kVA 60kVA 80kVA

High Frequency Online UPS 20KVA 30KVA 40KVA 60KVA 80KVA UPS EH9335 Pro Series(20-80KVA)The EH9335 Pro series UPS is three-in, three-out/three-in single-out. The product capacity covers all power segments from 20kVA to 80kVA, which is convenient for users to configure flexibly. This series of UPS can solve almost all power problems, such as power outage, city power high voltage, city power low voltage, voltage drop, amplitude reduction, Power problems such as high voltage pulses, voltage fluctuations, surge voltages, harmonic distortion, clutter interference, and frequency fluctuations.Features:Features(1) Three in three out / three in single out UPSThe series is a three-in and three-out UPS. The input current is three-phase balanced, which can equalize the load of the three-phase power grid; the output can be changed to single-phase output.(2) Digital controlAll parts of the UPS are digitally controlled. The UPS has excellent performance indicators, high system stability, self-protection and fault diagnosis capabilities, and avoids the risk of analog device failure, making the control system more stable and reliable.(3) The number of external batteries is optional (±16/18/20 sections are optional)The number of external batteries for this series of UPS can be selected according to the user's needs: ±16/18/20 knots.(4) Charging current can be setThis series of UPS automatically assigns a reasonable charge current by setting the user-configured battery capacity. Constant voltage charging mode, constant current charging mode and floating charging mode can automatically and smoothly switch.(5) Intelligent monitoring functionThis series of UPS can realize remote monitoring of UPS when an optional SNMP card is selected.(6) Smart charging methodThis series of UPS uses an advanced two-stage three-stage charging method.The first stage is high constant current charging, quickly recharge about 90% of the power; the second stage of constant voltage charging, can activate the battery characteristics and fully charge the battery; the third stage is floating charge mode.This can balance the goal of fast charging and extending battery life, saving users' battery investment.(7) LCD displayThis series of UPS uses LCD and LED dual display, which allows users to more intuitively understand the working status and operating parameters of the UPS such as input/output voltage and frequency load capacity, battery capacity and internal temperature, so that all operations can be seen at a glance(8) EPO FunctionAn emergency shutdown (EPO) button is embedded on the UPS unit panel,user can externally connect the EPO button. Press the EPO button in an emergency to shut down urgently; and have a remote emergency shutdown (REPO) function.6KVA 10KVA Online UPS PicturesSpecificationsModelEH9335-20KSEH9335-30KSEH9335-40KSEH9335-60KSEH9335-80KSPower20KVA /18KW30KVA /27KW40KVA /32KW60KVA /54KW80KVA /64KWInputInputThree-phase four-line + groundRated Power380/400/415VacVoltage Range208~478VacFrequency Range45-55Hz at 50Hz/54-66Hz at 60Hz (Auto sensing)Power Factor≥ 0.99Input Current Harmonic≤ 3%(100% Nonlinear load )  Bypass RangeBypass protection voltage upper limit:220V:+ 25%(Optional+ 10%,+ 15%,+ 20%);230V:+ 20%(Optional+ 10%,+15%);240V:+ 15% (Optional+10%)Bypass protection voltage lower limit:-45%(Optional -20%,-30%)Bypass frequency protection range:±10%OutputOutputThree-phase four-line + ground or single phase+NRated Voltage380/400/415Vac or 220/230/240VacVoltage accuracy±1%  Output FrequencyUtility Mode  Synchronous with input; when the mains frequency exceeds ±10% maximum(±1%, ±2%, ±4%,±5% can be set),the output frequency is 50*(±0.2)HzBatteryMode(50/60±0.2%)HzLoad Peak Ratio3:1Output Voltage Distortion≤ 2% Linear Load≤ 5% Nonlinear LoadBatteryEfficiencyNormal Mode≥ 94.5%Battery VoltageOptional :±192V±216V±240V DC (±16/18/20  P CS)Charging Current10A maxTransfer timeUtility mode to bypass mode: 0ms (tracking); utility mode to battery mode: 0msProtectionOverload CapabilityNormal ModeLoad ≤ 110%, 10mins, ≤ 125%, maintain 1mins, ≥ 150% shut down immediately.Over Temperature ProtectionNormal mode : Switch to bypass mode; Battery mode : Turn off the output immediately.Emergency shutdown (EPO)Turn off the output immediatelyOperating EnvironmentCommunication ConnectionUSB, RS485, dry contact, parallel (optional), SNMP card (optional), relay card (optional)Working Temperature0ºC~ 40ºCStorage Temperature-25ºC~ 55ºCRelative Humidity0 ~ 95%  No condensationAltitude< 1500m, when above 1500m, derate according to GB/T 3859.2Physical characteristicsSize (D*W*H)724*250*734mm805*335*978mmNet Weight(kg)45464880.582.5Executive standardYD/T1095-2008MUST POWER LIMITED Company Introduction:Must Power Limited devotes itself to power field since 1998, and has its own factory in 2008. Now it has 2 factories with about 300 regulor employees, including 40 engineers in R&D Department, 3 engineers in After-sales Service Center Department, 40 internation sales. MUST pro