1 or 3 Phase Rectifier Battery Charger Battery Regenerator/DC UPS/DC Power Supply

1 or 3 Phase Rectifier Battery Charger Battery Regenerator/DC UPS/DC Power supplyThe EverExceed uXcel range industrial battery charger is the flagship charger of EverExceed Industrial Power solutions. It integrates proven design topology with the latest advanced digital control technology to control the thyristor bridge rectifier and provides the most reliable and trouble-free performance in any electrical and industrial environments.Advantages:Large LCD display User friendly operation with large LCD display, optional touch screen with the choices of 8 languages ensure easy maintenance and operation.Smart communication and Remote MonitoringLeading Technology- 6 or 12 phase controlled Thyristor technology The embedded micro-computer controller processes signals 10 times faster than standard analog methods.Isolation transformer Multilingual digital graphic display with embedded event log. Full compatibility with lead-acid and nickel- cadmium batteries, sealed or vented.High Reliability and High MTBF  Precise adjustable temperature compensation, robust and unique design allows the charger to continuously operate at 40°C ambient temperature on full load. Natural ventilation and cooling are available on most of the cases.>Flexible maintenance and Reduced MTTR-The design make it easy for front-access to all vital modules modules of the charger >Versatile constant voltage and constant current charging modes >Smart communication and Remote Monitoring through isolated RS232, RS485, Ethernet. Full data logging >Long design life up to 20+years-system design life up to 20+ years in continuous operation under the condition of appropriate maintenance >Enhanced Robustness - Mechanical design to withstand vertical and horizontal acceleration stress up to 0.5g as standardFeatures:Flexibly customizedpower solutions to perfectly meet thespecific requirements of customer's industrial applications.Ruggedized solutionsto withstand harsh environments,extreme temperatures, humidity, dust and vibrations etc. Up to IP55 protection.Complete power protection solutionsincluding switchgear,DC distribution, monitoring suite.  Technical parameters:OUTPUTNominal DC voltage24/48/110/125/220/240/400Output voltage range0-1.5×nominal voltage (adjustable)Nominal DC current10-1500AOutput current range0-1.1×nominal current(adjustable)Voltage stability±1% in float mode, input within toleranceVoltage ripple1% RMS(with battery connected)Current LimitationBattery current limitation can be adjustedFiltering L-C FilterOutput ProtectionShort Circuit, NH Fuse and Overvoltage protection OPTIONSRectifierOther input voltageBlocking diodeSurge and Lightning protectionsVoltage ripple filterBattery circuit protection boxBatteryBattery reversed polarity detectionBattery low-voltage disconnection contactor (LVD)Battery room temperature sensorBattery cabinet / rackBattery monitoring systemParallel configurationsSystemDropping diodes/DC-DC converterEarth fault monitoringInternal cabinet lightingAnti-condensation heaterOutput breakerFront-panel analog meters/digtal metersDC distributionTemparature compensationAC high and AC low alarm/protectionDC high and DC low alarm/protectionAC fault alarmLED test functionOther frame colourMechanicalUp to IP55 externalPlate thicknessGalvanized sheetFront access maintenanceTop cable entrySpecial keylockSpecified cabinet identification (tag, nameplate)Modbus TCP/IPCommunicationmodbus RTU(RS485)DNP3.0 protocolVolt-free contactsTransducers 4-20mARemote monitoring BATTERYTypeLead acid or nickel cadmium, vented or recombination and Lithium battery COMMUNICATIONCommunicationRS232, Modbus RTU GENERAL DATAOperating temperature0 to 50 °CStorage temperature-20 to +70 °CRelative humidity< 95 % non condensingOperating altitude1000 m max without deratingCoolingFan cooling or Natural cooling according to ratingEfficiency90% according to ratingExternal protectionIP20Noise(at 1m in front of the unit)55 - 65 dB according to ratingCabinet colorRAL 7035DimensionsVarying according to ratings & options  STANDARDSIEC60146-1-1:2009Semiconductor converters - Specification of basic requirementsIEC62040-1:2008+AMD1:2013Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS in restricted access locationsIEC62040-2:2006Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirementsIEC61439-1:2011Low voltage switchgear and controlgear assemblies - Part 1: General rulesIEC60529:1989+AMD1:1999Degrees of protection provided by enclosures (IP Code)IEC60076-11:2004Power transformers - Part 11: Dry type transformers  European DirectivesLow voltage directive: 2006/95/EC and 2014/35/EUEMC directive: 2004/108/EC and 2014/30/EUCE MarkApplication:The EverExceed uXcel Premium Rectifier Charger range suits all DC applications requiring a large battery back-up:Power Transmission and DistributionContinuous process industriesOil and Gas and Petrochemical industriesTransportation (rail, metro, tramway) Why us? R