LCD/LED Home UPS 1000va 2000va

Basic Info.Model NO.PG power inverterPhaseSingleTypeDC/AC InvertersBrand NameStankupsWaveModified Sine WaveCapacity1000va 2000vaDisplayBoth LED & LCDWeight2.5kgOutput Voltage110V~240VACCharge Current10A/20ADC12V/24VSmart SizeYesWarranty1 YearTrademarkMUSTSpecificationCE/ISOOriginShenzhen, Guangzhou, ChinaProduct DescriptionSpecifications 1.1000va/2000va available 2.10a/20a charger 3.CPU control 4.LED/LCD display 5.Hot in Pakistan  LCD/LED home ups 1000va 2000va    1. FeaturesThe PG series converts DC power into AC power.With a continuous output and compact design,the units sideal for running TVs,Stereos,Laptop and computers and other home appliancies .PG series will automatically transfer to inverter and provide power when AC supply is interrupted unexpectedly. Super efficient, DC to AC conversion, minimizing charging losses10A/ 20A chargerInput voltage range selection optionFully automatic start operationHigh frequency technologyCompact size and light weightProvides critical overload protectionEco-friendly & non-polluting (green device)Advanced technology optimizes battery life MODEL   PG500 VA PG1000 VA PG20 00  VA CAPACITY   500VA/300W 1000VA/600W 2000VA/1200W AC INPUT Nominal Voltage 220/230/240VAC Input Voltage Range 90~280VAC Nominal Frequency 50/60Hz (Auto Detection) Input Voltage Range Selector Narrow 170~280VAC Wide 90~280VAC INVERTER MODE OUTPUT   Voltage 230VAC +10/-18% Frequency 50/60Hz ±0.5Hz Waveform Modified Sine-wave Efficiency (AC to AC) > 95% Efficiency (DC to AC) > 80% TRANSFER TIME Transfer Time ( AC to DC ) 20ms (Typical) 20ms (Typical) Transfer Time (DC to AC) 20ms (Typical) 20ms (Typical) BATTERY Nominal Voltage 12V DC 24V DC CHARGER Charging Voltage 13.7+/-0.2V 27.4+/-0.4V Charging Current 10A max. Overcharging Protection 16V+/-0.4V 32V+/-0.8V TRANSFER Transfer Time Typical 15-20ms, 40ms max INDICATOR Line Mode Green LED blinks or lights steadily Battery Mode Yellow LED lights Overload/fault Red LED blinks or lights steadily AUDIBLE ALARM Low Battery Voltage in Battery Mode Beeps every 2 seconds Overload Beeps every 0.5 second. Fault Beeps continuously ENVIRONMENT Temperature 0 ~ 40°C   PHYSICAL Dimension (mm) DXWXH 255x80x224 Net Weight (Kg) 2.0Kg 2.3Kg 2.5Kg PROTECTIONS Deep Discharge, Overcharge, Short Circuit, Overload, Battery Short, Over Voltage, Under Voltage.               3.Troubleshooting   Problem Possible Causes Remedy No LED display Battery Weak   1.  Re-charge battery Battery defective 2.  Battery replacement. Power switch is not pressed 3. Press and hold power switch. Mains normal but works in inverter mode AC Input  missing Check AC input connection.   2. Input protector is effective 2.  Reset the input protector. Alarm buzzer beeps continuously Overload   1.  Verify that the load matches the capability specified in the specs.   Back up time is shortened Overload   1.  Remove some non-critical load. Battery voltage is too low. 2.  Charge battery for 8 hours or more.