Online Transformerless Commercial 10-20kVA UPS with 3 Phase and 1 Phase

UC100-200 series UPS is a three-phase in and one-phase out high frequency tower-mounted UPS with an output power factor up to 0.9 and a strong load capacity. It adopts leading DSP online double conversion technology to provide high-level power protection. It supports flexible battery quantity configuration, flexible redundancy design and compatible to the generator to fit diverse environment. It has been widely used in small and medium IDC machine room, control center, industry process control fields and so on.General FeaturesTrue double-conversionDSP technology guarantees high reliabilityN+X parallel redundancyCompatible with three-phases and single-phase inputSelectable quantity of battery for each group:16/18/20 piecesAdjustable charging current via LCD3-stage charging design optimizes battery performanceECO mode operation for energy savingSelf-diagnosis at startupEmergency power off function(EPO)Maintenance bypass is convenient for maintenanceGenerator compatibleCommunications:RS-232,USB,Parallel card(Optional),SNMP card(Optional), Relay card (Optional)Cold start Technical SpecificationMODELUC100UC100LUC150LUC200LCapacity (VA/Watts)10K / 9K15K / 13.5K20K / 18KINPUT Nominal Voltage380/400/415Vac(3Ph+N+PE) or 220/230/240Vac(L+N+PE) Operating208~478Vac or 120VAC-276VacVoltage RangeOperating50Hz:45~55Hz,60Hz:54~66Hz Frequency RangePower Factor≥0.99BypassMax.voltage: 220V:+25%(Optional +10%,+15%,+20% ) Voltage Range         230V:+20%(Optional +10%,+15%) 240V:+15%(Optional +10% )    Min. voltage: -45% (Optional -20%,-30%)ECO RangeSame as bypassHarmonic≤5%(100% non-linear load)  Distortion (THDi)OUTPUT  Rated Voltage220/230/240VacPower Factor0.9Voltage Regulation±1%FrequencyLine Mode±1%/±2%/±4%/±5%/±10% of the rated frequency(Optional)Bat. Mode(50/60±0.1)HzCrest Factor3:01Harmonic≤2% with linear load Distortion (THD)≤5% with non-linear load Waveform Pure SinewaveTransfer TimeUtility to Battery : 0ms; Utility to Bypass: 0msEFFICIENCYEfficiencyUp to 94%Up to 94.5%BATTERYBattery VoltageSelectable Voltage: ±96/108/120VdcTypical6-8 hours (To 90% capacity)Recharge TimeCharging Current Maximum current 10APROTECTIONOverloadLine ModeLoad≤125%: last 5min;≤150%: last 1min;>150% 200msturn to bypass modeBypass Mode63A(Input breaker)100A(Input breaker)125A(Input breaker)Short CircuitHold Whole SystemOverheatLine Mode: Switch to Bypass; Backup Mode: Shut down UPS immediatelyBattery LowAlarm and Switch offINDICATORSAudible &Line Failure, Battery Low, Overload, System FaultVisual AlarmsStatus LED &Line Mode, Backup Mode, Eco Mode, Bypass Mode, Battery Low, LCD DisplayBattery Bad, Overload & UPS FaultParameters OnInput/Output Voltage, Input/Output Frequency, Load Level, Battery Level,The LCD PanelInner Temperature & Remaining Battery Backup TimeMANAGEMENTCommunicationRS-232,USB,Parallel card(Optional), SNMP card(Optional), Relay card (Optional) InterfaceENVIRONMENTOperating Temperature0ºC~40ºCStorage Temperature-25ºC~55ºCHumidity Range0~95% (Non-condensing)Altitude< 1500mNoise Level