Subrack Modular Lithium-Ion UPS 40-150kVA

The HPM3300E subrack modular UPS ranging from 40 to 150kVA has a compact structure. It is scalable and hot-swappable, making it ideal for customized cabinets, modular data centers and other applications. Matching with the lithium battery rack, HPM3300E lithium-ion UPS system can provide higher power density, smaller footprint, and longer life span. General FeaturesAll units adopt modular design, including power module, bypass module, monitoring module, which can be easily integrated in MDC or customized cabineteWide input voltage range, line voltage range is 138-485VParallel redundant configuration (Max 8 units) to enhace reliability.High input power factor 0.99, high efficiency 96.5% and ECO mode to save energyLBS funtion & Strong load capacityIntelligent management:Standard colorful touch screen Compatible with generator VRLA & Lithium battery supportable  Technical SpecificationModel HPM3300E-RM-40HPM3300E-RM-50HPM3300E-RM-60Cabinet ModelHPM3300E-80HPM3300E-120HPM3300E-100HPM3300E-150HPM3300E-120Cabinet capacity (VA)40k~80k40k~120k50k~100k50k~150k60k~120kModule capacity (VA)40k50k60kMax. number2+132+132+1InputNominal voltage380/400/415Vac, (3Ph+N+PE)Operating voltage range138~305Vac for 40% load; 305~485Vac for 100% loadOperating frequency range40Hz~70HzPower factor≥0.99Harmonic distortion (THDi)≤3% (100% linear load)Bypass voltage rangeMax. voltage:220V: +25% (optional+10%, +15%, +20% ); 230V: +20% (optional +10%, +15% ); 240V: +15% (optional +10%)Min. voltage: -45% (optional-10%, -15%, -20%, -30%)Bypass frequency range±10%Power Walk InSupportGenerator inputSupportOutputRated voltage380/400/415Vac, (3Ph+N+PE)Power factor1Voltage regulation±1%OutputLine modeSynchronize with input, when the input frequency >±10%(±1%/±2%/±3%/±4%/±5% optional), output 50/60 (±0.1Hz)frequencyBat. mode(50/60±0.1%)HzCrest factor03:01Harmonic distortion (THDv)≤2% with linear load; ≤4% with nonlinear loadEfficiency96.50%Battery VRLA battery360Vdc~600Vdc (30~50pcs continuously adjustable, 30pcs default, 36~50pcs no powerBattery voltagederating; 32~35pcs output power factor 0.9; 30/31pcs output power factor 0.8) Lithium battery512VdcPower module charge current20A (Max.)System featuresTransfer timeUtility to Battery : 0ms; Utility to Bypass: 0msOverloadLine mode≤110%, 60min; ≤125%, 10min; ≤150%,1min to bypass; >150%, shut down immediatelyBypass mode30ºC:135% overload for long term; 40ºC:125% overload for long term; 1000% overload for 100 msOverheatLine Mode: Switch to Bypass; Backup Mode: Shut down UPS immediatelyLow battery voltageAlarm and Switch offSelf-diagnosticsUpon Power On and Software ControlBackfeed protectionSupportBatteryAdvanced Battery ManagementNoise suppressionComplies with EN62040-3Audible & visual alarmsLine Failure, Battery Low, Overload, System FaultStatus LED & LCD displayLine Mode, Bypass Mode, Battery Low, Battery Fault, Overload & UPS FaultReading on the LCD displayInput, Output, Battery, Command, Setting, MaintenanceCommunication interfaceRS232, RS485, Parallel, LBS, BMS, Dry contact port, Relay card(optional), SNMP card(optional), Battery temperature sensor(optional)Operation EnvironmentOperating temperature0ºC~40ºCStorage temperature-25ºC~55ºCHumidity range0~95% (non condensing)Altitude1500mNoise level