UPS Lead Acid Rechargeable Solar Panel Power Battery (12V24ah, 12V38ah, 12V50ah, 12V55ah, 12V65ah, 12V100ah, 12V120ah, 12V150ah, 12V200ah, 12V250ah)

Test Result of 60KG 12V200Ah AS BELOW.ItemLoopStep.Time(hours)TypeCharge/DischargeOperation TimeVoltage(V)Current(A)Capacity(AH)Temperature(ºC)Power(WH)11000:00:00                  0000:00:0013.040025021100:00:00  FV    Discharge0000:00:0013.0420025031100:30:00  FV    Discharge0000:30:0012.6319.991025126.441101:00:00  FV    Discharge0001:00:0012.59202025252.551101:30:00  FV    Discharge0001:30:0012.55203025378.261102:00:00  FV    Discharge0002:00:0012.5120.014025503.571102:30:00  FV    Discharge0002:30:0012.4619.985025628.381103:00:00  FV    Discharge0003:00:0012.4120.016025752.791103:30:00  FV    Discharge0003:30:0012.3619.997025876.5101104:00:00  FV    Discharge0004:00:0012.31208025999.9111104:30:00  FV    Discharge0004:30:0012.2519.9990251122.7121105:00:00  FV    Discharge0005:00:0012.1919.98100251244.9131105:30:00  FV    Discharge0005:30:0012.1319.98110251366.6141106:00:00  FV    Discharge0006:00:0012.0720120251487.6151106:30:00  FV    Discharge0006:30:001219.99130251607.9161107:00:00  FV    Discharge0007:00:0011.9420140251727.6171107:30:00  FV    Discharge0007:30:0011.8720150251846.6181108:00:00  FV    Discharge0008:00:0011.7819.99160251964.9191108:30:00  FV    Discharge0008:30:0011.719.99170252082.3201109:00:00  FV    Discharge0009:00:0011.620.01180252198.9211109:30:00  FV    Discharge0009:30:0011.520190252314.5221110:00:00  FV    Discharge0010:00:0011.3620200252428.8231110:30:00  FV    Discharge0010:30:0011.1619.98210252541.5241110:56:35  FV    Discharge0010:56:3510.819.99218.87252639251200:00:00  LV    Charge0010:56:3510.839.60250261200:30:00  LV    Charge0011:26:3512.5239.4619.7325243.7271201:00:00  LV    Charge0011:56:3512.6939.4639.4625492.4281201:30:00  LV    Charge0012:26:3512.8439.4659.1925744.4291202:00:00  LV    Charge0012:56:351339.4678.9225999.3301202:30:00  LV    Charge0013:26:3513.1539.4698.65251257.2311203:00:00  LV    Charge0013:56:3513.3339.46118.38251518.5321203:30:00  LV    Charge0014:26:3513.5539.46138.11251783.6331204:00:00  LV    Charge0014:56:3513.8539.46157.84252053.7341204:30:00  LV    Charge0015:26:3514.2339.46177.57252330.6351205:00:00  LV    Charge0015:56:3514.534.12196.79252607.7361205:30:00  LV    Charge0016:26:3514.5120.86210.38252804.8371206:00:00  LV    Charge0016:56:3514.511.41218.3252919.6381206:30:00  LV    Charge0017:26:3514.56.36222.63252982.3391207:00:00  LV    Charge0017:56:3514.53.89225.14253018.7401207:30:00  LV    Charge0018:26:3514.52.62226.73253041.8411208:00:00  LV    Charge0018:56:3514.511.85227.81253057.4421208:30:00  LV    Charge0019:26:3514.491.35228.59253068.7431209:00:00  LV    Charge0019:56:3514.51.05229.17253077.3441209:30:00  LV    Charge0020:26:3514.50.8229.64253084451210:00:00  LV    Charge0020:56:3514.490.7230.03253089.6461210:30:00  LV    Charge0021:26:3514.510.56230.36253094.4471211:00:00  LV    Charge0021:56:3514.50.59230.64253098.5481211:30:00  LV    Charge0022:26:3514.50.56230.9253102.3491212:00:00  LV    Charge0022:56:3514.50.41231.13253105.6501212:30:00  LV    Charge0023:26:3514.510.37231.34253108.7511213:00:00  LV    Charge0023:56:3514.510.41231.54253111.6521213:30:00  LV    Charge0024:26:3514.50.39231.72253114.2531214:00:00  LV    Charge0024:56:3514.510.37231.9253116.7541300:00:00  END             0024:56:3514.5100250♦ Our factory was Founded in 2008 , 2 million batteries annual production capacity ♦ Products including UPS battery /Solar Battery / Deep cycle battery /VRLA battery /Sealed Lead Acid battery /Emergency Battery /12v Battery /Backup battery /Sealed Battery /Emergency Light Battery /Valve Regulated Lead Acid battery /Storage battery /rechargeable battery /Uninterrupted  power battery /EPS battery /wind battery /Communication System battery /Inverter battery♦ Products are exported to more than 150 countries ♦ Products are certified by CE , and FCC, MSDS, ISO and SGS certification♦ Mature and very well respected AGM and GEL technologies for valve-regulated lead-acid batteries ranging from 2Ah to 3000AhAdvantage:1. The battery is full of power when it's out of factory, no need to use liquid charge;2. no memory, no need to discharge battery use, suitable for circuit design;3. by high partition, adsorption and strong;4. there is no flowing liquid (poor liquid), does not leak acid and free Upside down,5. comply with environmental requirements, ease of use,6. the use of lead-calcium alloys, battery self-discharge is very low,7. easy storage, less maintenance;8. using ABS plastic shell and valve technology for safe use.Application:1.Green energy systems (solar, wind, hydro, etc)2.Solar power stations 3.UPS systems4.Electricity power supply systems (EPS)5.Telecom installations6.boats or buoys7.Signal station8.Survey and Mapping system9/Emergency lighting10.Traffic lights11.Street lighteningMore Products:BatteryModelNominal voltage(V)Ratedcapacity (Ah)20hrs/25ºCApprox.weightDimensionTerminal Type kglbsLengthWidthHeightTotal Height mminchmminchmminchmminch PTG33-12123310.4022.931967.721315.161556.111707.09T9,16PTG38-12123811.2029.76197