CO2 Controller with Dual Beam Ndir Remote Sensor Monitor Day and Night for Hydroponics

Product DescriptionThe Wall Mount CO2 Controller AGc30, with built-in Dual Beam NDIR technology and Day/Night auto detect sensor, is specially designed to measures CO2 level for greenhouse and ventilation. The AK C30 also helps to extend your measure spot away from the display with 4.5 meters long cable connected to the remote sensor.Its relay output could control the other connected devices, such as CO2 generator to produce in a greenhouse when the CO2 concentration is below to help increase plant yields by supplying CO2 required for photosynthesis.It is perfect used in agricultural applications like greenhouse/ hydroponics rooms, plant factories with both audible and visual alarms.Basic Info.Model NO.AGc30Buzzer Sound80dB @10cmTrademarkOEM/ODMPower SourceAC 100 ~ 240 VACSensor TypeDual-Beam NDIROriginChina KunShanCO2 Range0~5000ppmHS Code9027100090Display TypeLCDProduction Capacity80000 Pieces/YearPhoto CellAuto detect Day/NightTransport PackageCartonSensor Unit Size153*33*27mm   (6.0*1.3*1.1inch)Package Type1 pcs/Color BoxControl Unit Size195*145*44mm195  (7.7*5.7*1.7inch)Weight700g ( 24.7oz) Feature:Ø  Dual Beam NDIR (Non-Dispersive-Infrared) technology is used to improve the long term stability.Ø  CO2 controller; TracerØ  Built-in Day/Night detect sensor Ø  Chart with variable time Zoom LevelsØ  Foolproof "Hold Home" functionØ  Good Zone display indicate  Ø  Remote Sensor   Product ParametersLCD Display:Trend Chart Zoom:Below is a table that show the available Zoom Levels for all parameters CO2, as well as the duration of each division for corresponding Zoom Levels:Auto Detect Day/Night:The built-in Photo-Cell sensor can automatically detect whether it is Day or Night. It can override the CO2 control and shut off the CO2 generator by turning off the output power during the night. Conversely, if the Photo-Cell detects light and the CO2 level is low, the device will start the CO2 generator by turning on output power.Output Control:Output power is on when CO2 concentration is over Set Center+(1/2) Set zone, and off when CO2 concentration is below Set Center-(1/2) Set zone. For example, if the Set Center is 1200ppm, and the Set zone is 400ppm, the output power will shut off when CO2 over 1200+(1/2)*(400)=1400ppm,  and power on when CO2 below 1200-(1/2)*(400)=1000ppm.Specifications:Typical test conditions, unless otherwise specified:  Ambient Temp =23+/-3°C, RH=50%-70%, Altitude=0~100 meterMeasurementSpecificationOperating Temperature32°F to 122°F (0°C to 50°C)Storage Temperature-4°F to 140°F (-20°C to 60°C)Operating & Storage RH0-95%, non-condensingCO2 Measurement Accuracy  at 0~3000ppm±50ppm or ±5% of reading, whichever is greaterAccuracy  over 3000ppm±7%Repeatability20ppm at 400ppm (standard dev. of 10 readings in 1 minute)Measurement Range0-5000ppmDisplay Resolution1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000)Temp Dependence±0.2% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25°C Pressure Dependence0.13% of reading per mmHg (corrected by user's altitude input)Response Time