Special Frequency Conversion Dedicated Ball Mill Frequency converter with Control Cabinet•EM318C series special frequency conversion control cabinet for ball mill has the following characteristics:•Low-frequency and high-torque stable operation: 0.5Hz/150% rated torque is output smoothly, ensuring smooth start-up of the ball mill;•Convenient man-machine interface (touch screen), it is convenient to set multi-segment running time and operating frequency of each time period, and it is convenient to view current and voltage and other operating information through the man-machine interface;•Excellent current limiting ability: ensure that the control cabinet does not trip when the load fluctuates frequently;•Wide voltage input range, automatic voltage stabilization: to ensure that when the grid voltage drops, the output can still meet the torque output requirements of the lifting equipment;•Wide range of speed regulation: meet the requirements of light-load high-speed and heavy-load low-speed hoisting equipment, and improve the working efficiency of the equipment;•Modubus communication interface is used to check the working status of the inverter;•Instantaneous power failure non-stop function, can automatically feed back electric energy to ensure a certain torque output;•The frequency converter and the motor can be used with the same power without enlarging the capacity of the frequency converter;Product Description  Product ParametersStandard machineAuxiliary Solution F4-28=1Without Auxiliary SolutionF4-28=2F0-04=0 keyboard controlF0-04=1Terminal controlF0-04=1 Terminal controlF0-05=0Two-wire control 1F0-05=2Three-wire control 1F0-05=2Three-wire control 1F0-09=15.00Acceleration timeF0-09=35.00Acceleration timeF0-09=35.00Acceleration timeF0-10=15.00Deceleration timeF0-10=35.00Deceleration timeF0-10=35.00Deceleration timeF0-19=0 Normal startingF0-19=1 Speed Tracking StartF0-19=1 Speed Tracking StartF0-20=0 Normal StopingF0-20=1 free StopingF0-20=1 free StopingF0-26=0 General speed setting methodF0-26=1 Special speed setting methodF0-26=1 Special speed setting methodF0-27=0 normal menu modeF0-27=1 Advanced menu modeF0-27=1 Advanced menu modeF2-00=1RUNF2-00=1RUNF2-00=52Corsair boot startingF2-01=2  +/- SwitchF2-01=51 External fault inputF2-01=51 External fault inputF2-02=3Multi-speed terminal 1F2-02=49 Program run resetF2-02=49 Program run resetF2-03=4Multi-speed terminal 2F2-03=18 three-wire stopingF2-03=18three-wire stopingF2-04=5Multi-speed terminal 3F2-04=9 free StopingF2-04=5Multi-speed terminal 3F2-12=0Inverter workingF2-12=33 Motor fan delayF2-12=33 Motor fan delayF2-13=1Frequency output FARF2-13=0Inverter workingF2-13=0Inverter workingF9-28=0 Maximum frequency speed trackingF9-28=1 Stoping frequency speed trackingF9-28=1 Stoping frequency speed tracking   Installation Instructions        ModelWW1HH1DD1D2dGravity Center HeightEM318C-110-35003901550143052041034013920EM318C-132-3EM318C-160-350039016501530520410340131000EM318C-185-3EM318C-200-3EM318C-220-365555017501600600490420131030EM318C-250-3EM318C-280-3EM318C-315-380069017801600600490420131070EM318C-355-3Company Profile/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1