Cesi Kema IEEE IEC ISO CE 20 Years Professional Transformer Manufacturer 3810kVA 10kv Rectifier Transformer

Company IntroductionShenda ( In full: Shenda Electric Group Co.,Ltd.)  is one of the leading manufacturers in the power transmission & distribution industry. Founded in 2000 and currently employs about 1,100 employees worldwide. Shenda operates four factories (three in China and one in the United States of America - R. E. Uptegraff Manufacturing Company, LLC of Pennsylvania, U.S.A.).  Shenda also owns other ten subsidiaries throughout China. The annual gross sales is USD$250 million in 2015.Shenda's annual total production capacity is about 18,000,000 KVA, Our main products include oil immersed power transformer(up to 250MVA/ 330kV) , dry type transformer(up to 20MVA/35kV), combined transformer substation, amorphous alloy transformer, rectifier transformer (100MVA/220kV )and especially furnace transformer(180MVA/220kV). Our products' performance measures up to the standards established by International Electric Committee (IEC). shendaelectric.en.made-in-china.comCertifications100MVA/220kv power transformer short circuit test report -issued by CESI Italy&CTQC China 120MVA/33KV oil EAF transformer 50MVA/69KV oil power transformer 10MVA/33kv dry-type transformer Type test report -issued by KEMA Netherlands 63MVA/110KV Power transformer short circuit test report -issued by CTQC China 12.5MVA/22KV Rectifier transformer routine test -issued by V-Check korea ISO 9001&ISO14001&OHSAS 18001 CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR Test labTesting are conducted for every transformer before delivery.Tests are classified to be routine tests and type test. A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers - Measurement of winding resistance . - Measurement of voltage ratio and check of phase displacement. - Measurement of short circuit impedance and load losses. -Measurement of no-load losses and current . -Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) . B - Type tests : The following tests shall be carried out - Temperature rise test - Lightning impulse test C - Special tests : - Determination of noise level according to IEC 60551 . - Oil leakage test - Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in     the report test also hot spot temperature rise must be calculated and recorded on the report test ) . - Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted). Client inspectionPackaging and transportationFactory documentation 1Technical parameters2Outline drawing3Lifting diagram4Nameplate drawing5Control box drawing6Transportation diagram7Transformer install manual8Transformer operation / Maintenance instruction9Principles parts / components ex-work certification and operation instruction10Recommended spare part for 2-5 years operation11Test reports (routine test / type test / special test)12Etc…Engineering ServicesDuring the design process, client will be permitted to come to factory to take a supervision and guidance, manufacture and acceptance test. We provide engineering services like pre-commissioning / commissioning / install and operation consult support / technicians training on site. We provide after-sales service.We provide 12 months warranty of quality and performance  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1