1. OVERVIEW1. The FR-ZJB transformer neutral point gap grounding
protection device is specifically designed for the neutral point of
110KV, 220KV, 330KV, and 500KV power transformers. It enables the
transformer to operate with either grounded or ungrounded neutral
point, thus avoiding damage to the transformer caused by high
neutral point voltage due to system faults. This product is widely
used in the fields of power, metallurgy, petrochemical,
construction, and environmental protection.2. Generally speaking,
rod gaps have highly uneven electric fields, unstable discharge
voltages, and large dispersion, which determines their poor
protective performance. Sphere gaps have uniform electric fields,
stable discharge voltages, and small dispersion, resulting in
better protective performance. Sphere gaps are easier to adjust
on-site, allowing users to adjust them according to their local
conditions. On the other hand, aligning rod gaps with pointed tips
is particularly difficult, making on-site adjustment more
challenging. Sphere gaps require high-quality stainless steel balls
with silver plating, which increases the cost and has strict fixing
requirements. Therefore, many manufacturers choose rod gaps to
reduce costs without considering the effectiveness.3. Current
transformers selection: Dry-type current transformers cast with
epoxy resin are used. The current transformers are installed in
stainless steel enclosures, which are not affected by environmental
conditions and have a long service life. This ensures that the
protection system does not experience false tripping or failure to
trip, and remains stable and reliable.2. PRODUCT FEATURES1).
Innovative design, easy installation The FR-ZJB transformer neutral
point gap grounding protection device integrates electrical
equipment such as isolation switches, zinc oxide surge arresters,
discharge gaps, and current transformers into a complete set of
equipment. It has the characteristics of small size, convenient
installation and debugging, and high reliability.2). Effective
protection, stable characteristics The FR-ZJB transformer neutral
point gap grounding protection device mainly adopts a spherical
discharge gap, which has higher accuracy, less dispersion, and
stable characteristics compared to the conventional rod-shaped
discharge gap. It accurately and effectively coordinates with the
characteristics of the surge arrester and the insulation of the
main transformer, with a large thermal capacity and less
susceptibility to burnout. It improves the safety and effectiveness
of protection.3). Flexible configuration, convenient to use The
FR-ZJB transformer neutral point gap grounding protection device
adopts a spherical gap, but can also be equipped with a rod-shaped
gap according to user requirements. The surge arrester and
isolation switch can be flexibly combined and selected according to
engineering needs. The operation of the isolation switch can be
manually or electrically controlled according to project
requirements. The technical parameters of the gap can be adjusted
and calibrated at the factory or on-site.4). Strong technical
capabilities, attentive service Our company is a professional
manufacturer with strong technical capabilities. We provide timely
technical communication and consultation before sales. We also
offer installation and technical guidance according to user
requirements after sales3. GENERAL WORKING CONDITIONS1). Suitable
for indoor and outdoor use.2). Ambient temperature: not lower than
-40°C, not higher than +55°C; relative humidity: not greater than
95% (25°C).3). Altitude does not exceed 4000m, and special
customization is available for altitudes above 4000m according to
actual conditions.4). Suitable for areas with seismic intensity of
8 degrees or below; maximum wind speed does not exceed 35m/s.5).
Grid frequency: 58-62Hz (for 60Hz systems), 48-52Hz (for 50Hz
systems).6). The air in the installation location should not
contain chemically corrosive gases and vapors, and should be free
of explosive dust.4. INSTRUCTIONS FOR USE1). When placing an
order, please provide the rated voltage of the transformer, the
turns ratio of the current transformer, the rated current of the
isolation switch, the form of the operating mechanism, and the
rated voltage of the zinc oxide arrester. If not specifically
specified, delivery will be made according to the technical data
standards specified in this manual.2). Two secondary windings with
a ratio of 0.5/10P should be provided for the secondary side of the
current transformer for measurement and protection purposes. When
not in use, it should be short-circuited.3). The wire cross-section
and type connected to the neutral point of the transformer shall be
determined by the user.5. INSTALLATION REQUIREMENTS1). During
installation, the equipment can be lifted using a base, and the
lifting rope should not be tied to the porcelain column to prevent
damage to the equipment.2). The fixing mechanism and the
Related products about Fenarro Neutral Grounding Protection Device for Transformer
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup