Lightning Arrester, Surge Arrester, Pararrayos, Parafoudre 3-132kv, 10ka

METAL OXIDE SURGE ARRESTERPolymer housed for outdoor applicationFeatures Better Electrical performance & reliability Ease of Installation-Light weight & smaller size Better Operating conditions Explosion & shatter proof & less mechanical damage to nearby equipments Better performance in polluted environment Vandalism resistant Free from Moisture ingress Higher safety Higher mechanical strength Insensitive to UV radiation High resistance to Ozone & Corona Excellent Tracking resistance Performance Data System Voltage Rated Voltage (kV):0.1-275 Nominal discharge current (kA) High current capability (4/10us) kA Energy Class : Energy absorption Capability kJ/kV Short Circuit (Pressure relief) kA:40 Standard in accordance with:IEC60099-4 Porcelain housed for outdoor application  For protection of transformer & switchgear. Highly non-linear MOV. Explosion Proof - Pressure Relief Design. High energy handling capacity. Glazed brown Porcelain Housing. Corrosion proof Aluminum alloy metal flange. Suitable for Ambient -400C to +550C. manufactures effective surge protection device with the modern technology of highly non-linear Zinc Oxide Varistor blocks and thus diverts natural lightning surge and switching surge to earth and simultaneously clip off any follow on current. Our station class arresters are designed to provide maximum safety to personnel and sub-station equipment even at the enormous short circuit duty. Research and Development is an ongoing process at Elektrolites with the active collaboration of experts in the industry. CONSTRUCTION & OPERATING PRINCIPLE   Lightning Arrestors  11kV      No.DETAILUNITSDATA Type 11kV gapless type metal oxide surgearrester - Distribution class1.Nominal  system  voltagekV112.Highest system voltagekV123.Basic Insulation Level  (BIL)kV95  3.   Ratings and type of surge arrester  4.Specification to which surge arrester complies IEC60099-45.Rated voltage of surge arresterkV106.Nominal, 8/20 µs, discharge current rating ofsurge arresterkA107.Maximum continuous operating voltage ofsurge arresterkV7.38.Gapless or gapped type metal-oxide surgearrester Gapless9.Material of insulation High temperature vulcanised siliconrubber10.Rated frequency of surge arresterHz5011.Design altitude of surge arrester (above sealevel)m1 400m12.Design ambient temperature of surge arresteroC-1 to4013.Specific creepage distance of surge arrester.mm/kV25 Automatic earth lead disconnectorsrequirements  14.Automatic earth lead disconnectors to be fittedYes/NoYES      15.Corrosion protection of metal and alloy parts:galvanising specification and/or stainless steel grade To SABS 763, 316 Tests  16.Previous type test results/certificate to beprovided with bidYes/NoYes17.Routine test results/certificate to be providedon deliveryYes/NoYes18.Drawing showing dimensions of the arrestor tobe provided with the bidYes/NoYes19.Minimum one minute wet power frequencywithstand voltage of external insulation of surge arrester housingkV2820.Maximum steep current impulse residualvoltage for a 10 kA, 1/20 µs, discharge currentkV5021.Maximum lightning impulse residual voltagefor a 10 kA, 8/20 µs, discharge currentkV4022.Lightning, 1,2/50 µs, impulse withstand levelof external insulation of surge arrester housingkV9523.Line discharge class rating 124.Long duration current, 2 000 µs, impulsewithstandA250 A25.High current, 4/10 µs, impulse withstandkA100 kA26.Automatic earth lead disconnector to be testedin accordance with IEC 60099-4Yes/NoYes                      33kV        S/NTECHNICAL DETAILSUNITSDATA1.Type 33kV gapless type metaloxide surge arrester -Distribution class2.Nominal  system  voltagekV333.Highest system voltagekV364.Power frequencyHz505.Basic Insulation Level  (BIL)kV170  3.   Ratings and type of surge arrester  6.Specification to which surge arrester complies IEC 600997.Rated voltage of surge arresterkV298.Nominal, 8/20 µs, discharge current rating of surge arresterkA109.Maximum continuous operating voltage of surge arresterkV2210.Gapless or gapped type metal-oxide surge arrester Gapless11.Insulation Material Silicon rubber12.Cantilever strength of surge arresterNm30013.Rated frequency of surge arresterHz5014.Design altitude of surge arrester (above sea level)m1 400m15.Design ambient temperature of surge arresteroC-1 to 4016.Minimum phase-to-ground specific creepage distance ofsurge arrester.mm/kV25 Automatic earth lead disconnectors requirements  17.Automatic earth lead disconnectors fittedYes/NoYes18.Corrosion protection of metal and alloy parts: galvanising To  SABS 763, 316            specification and/or stainless steel grade   Tests  19.Previous Type Test reports/certificate  from recognizedauthority to be provided with bidYes/NoYes20.Minimum one minute wet power frequency withstandvoltage of external insulation of surge arrester housingkV7021.Maximum steep current impulse residual voltage for a 10kA, 1/20 µs, discharge currentkV99.722.Maximum lightning impulse residual voltag