100A PC Class ATS Automatic Changeover Switch (RDS3-100B)Radin
Electric provides ATS design, engineering, and full after
sales support for a wide range of automatic transfer switch
applications. We offer onsite electrical audits to assist in
determining the correct product and installation to meet your exact
needs and requirements. RDS3 SeriesProduct NameRDS3 Series Dual
Power Automatic Transfer SwitchTypeClass PC StandardIEC
60947-6-1Poles3P/4PUse CategoryAC-33BTechnical
DateTypeRDS3-125RDS3-250RDS3-630Rated Working current (A)
le125A250A630ARated Working voltage (V)
Ue400400400Rated Insulation voltage (V) Ui800800800Rated
impulse withstand voltage (KV) Uimp888Use
categeoryAC-33BAC-33BAC-33BRated short time withstand current
(KA,rms) Icw10KA (200MS)10KA (200MS)25KA (200MS)Rated short circuit
making capacity (KA,peak) Icm20KA30KA50KARated limit short
circuit current (KA)Iq120kA120kA120kARated control power supply
voltage (V) Us230V230V230VContact transfer time
(s)1.51.82Operationcyclesno electricify850070003000with
electricify150010001000Total1000080004000Outline size (mm)
WxDxH245×130×122295×175×175430×272×228Weight (kg)51020Ats Function
List RDS3-BRDS3-EImages Controlpower voltageAC230VAuto
transferAuto transfer auto recovery, auto transfer no auto
recovery, power grid-generatorManual transferManual main power,
manual backup power, manual OFFIsolation lockOff position have
isolation function, also can be padlock lockedGenerator
controlGenerator start and stopFire linkagewith passive fire
linkage signal to switch OFF the device, with one set passive NO
feedback contactDisplay modeMechanical indication: device ON/OFF
status, operating modeLED: Running status LED indicator for I/II
POWER source and I/II ON/OFF statusMechanical indication: device
ON/OFF status, operating modeLED: Running status LED indicator for
I/II POWER source and I/II ON/OFF statusLCD: Settable keyboard and
voltage, frequency, display.Controller featuresThree phase
over/under voltage monitering. Set I/II/NO source priority,
over/low-voltage value, over/under frequency value, transfer time
delay, weekly/monthly/engine exerciser.Power monitoringABC three
phase over-voltage 265VABC three phase low-voltage 187VABC three
phase voltage missing monitor(other voltage customizable)ABC three
phase over-voltage (240-290V adjustable)ABC three phase low-voltage
(150-200V adjustable)ABC three phase voltage missing monitor(other
voltage customizable)Delay time Transfer delay (0-300s
adjustable)Recovery delay (0-300s adjustable)Generator start, stop
delay (0-300s adjustable)Mounting modeIntegated mountingLCD
separable mounting RADIN ATS Features Comparing, RDS2 --
RDS3 RDS2RDS3 Controller
FunctionsSimilarUtilization Category
(IEC)AC-32BAC-33BCertificatesCE, RoHSTUV, CEContacts and
CopperSilver coated copperHigh density silver alloy with technical
know-howLCDSelectableSelectableArc ChutesNoYesSizeCompactSmaller
than RDS2RDS3 Advantages:a. Control power voltage:AC 230V b. Auto
Transfer: Auto transfer auto recovery,auto transfer no auto
recovery,power grid-generator c. Manual transfer: Manual main
power,manual backup power,manual OFF d. Isolation lock: Off
position have isolation function,also can padlock locked e.
Generator control: Generator start and stop f. Fire linkage: With
passove fire linkage signal to switch OFF the device,with one set
passive NO feedback contact. g. Display mode: Mechanical
indication;device ON/OFF status operating mode LED: device
ON/OFF status,power status LCD: device ON/OFF status,power
status,data setting h. Setting mode: Key-press
operation,Chinese/English display interface,can set the working
mode,low-voltage value, over-voltage value, delay time, auto
transfer mode etc. i. Power monitoring: ABC three phase
over-voltage (240-290v adjustable)
ABC three
phase low-voltage (150-200v adjustable)
ABC three phase missing monitor
j. Delay time: Transfer delay (0-300s adjustable)
Recovery delay (0-300s adjustable)
Generator start,stop delay (0-300s adjustable) k.
Mounting mode: Integated mounting Controller Type:A: Basic
type single phase monitor B. Standard type threee phase
monitor+fire-fighting,generator control C: Intelligent type three
phase monitor+ fire-fighting,generator control+LCD display D:
Intelligent type three phase monitor+ fire-fighting,generator
control+split LCD display Working conditionsa. Ambient temperature:
-20ºC---+40ºC; 24 hours average not more than +35ºC b. Atmospheric
conditions: humidity not more than 50% at max. +40ºC,higher
humidity is allowed at lower temperature,at most wet month,the
average max humidity is 90% at the average min temperature
+25ºC,and have considered the condensation on the product surface
due to temperature variation; c. Altitude: Not more than 2000m d.
Pollution Class: The installation site environment pollution class
3 Dlivery TermsSea Shipment & Expre
Related products about 100A PC Class ATS Automatic Changeover Switch (RDS3-100B)
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup