Product DescriptionSafety light curtains are also photoelectric
safety protection devices (safety protectors, punch protectors,
infrared safety protection devices, etc.). In modern factories,
people and machines work together, and they can be installed on
some potentially dangerous mechanical equipment to protect workers.
Prevent security incidents from happening. For Example, stamping
machinery, shearing equipment, metal cutting equipment, automated
assembly lines, automated welding lines, mechanical transmission,
and handling equipment, and hazardous areas (toxic, high pressure,
high temperature, etc.), are likely to cause personal injury to
operators, can be installed.1. The unique structural design ensures
that there is no blind spot in the entire protection area;2.
Dual-channel OSSD output function, which can be cross-monitored
with each other;3. The self-diagnosis function can detect the
failure circuit module of the light curtain. and issue an alarm
signal;4. With interlock reset, external test, and EDM function,
strengthen the output monitoring ability;5. Adopt optical
communication synchronization, simplify the electrical connection
and make the operation easier;6. Meet the requirements of
Type 4, SIL3 and PLe safety levels, and can be used for the
protection of various parts of the body;7. Waterproof design to
meet outdoor applicationsDetailed PhotosProduct Application
Product ParametersLSA series safety light curtain
ModelLSA10LSA20LSA40LSA80General parameters :Space between
beams10mm20 mm40mm80mmNumber of optical
beams32~19216~9608~4808~24Min detection object15 mm26 mm46 mm86
mmDetection distance0.5 m ~6m0.5 m ~8mLight source850nm
infrared lightProtection height320mm...1,920 mmMechanical and
electronic parameters:Supply voltage:24v DC ± 20%Power consumption
≤5WPower-on delay2sWorking current Max.300 mAResponse
time3ms~52ms(depends on the optical beams quantity)Safety output
OSSD2-ways NPN/PNP Normal close; Short circuit protection,
Cross circuit monitoring ;output current< 200mA(30v DC)
Switch-on voltage drop :≤1.5v; Cutoff voltage :≤
1.2V; Load capacitance :30nF; Load inductance :2.2H;
Power supply cable resistance :≤ 10Ω; OSSD Test pulse
width :200 ~ 300us; OSSD Test pulse period :50 ~ 100ms;EDM
Selecting inputThe input is suspended or connected to low
level, the EDM input is invalid and connected to high level, the
EDM input is valid; High level: 10 ~ 30V DC, current
less than 10mA; Low Level: 0-2V DCEDM( External equipment
monitoring )inputThrough the EDM input terminal, the 24V DC signal
from the external equipment contactor can be monitored. High
level: 10 ~ 30V DC, current less than 10mA; Low Level: 0-2V
DCRESET(Reset)inputManual reset: RESET input terminal is connected
to high level through manual switch. Automatic reset: RESET input
terminal is connected to high level. High level: 10 ~
30V DC, current less than 10mA; Low Level: 0-2V
DC.IndicatorsPower(Green
),Fault(Yellow),Shelter(Red),Alignment(Blue 3 pieces).Communication
Optical synchronization Protection rateIP65Work
temperature-25ºC~50ºC RH 15~95%ConnectorM12,6
Pins(Emitter),8 Pins(Receiver)DimensionAs per models LSA20
seriesModelDetection Distance(m)Resolution ratio (mm)Light
beamsquantitySafe height (mm)Responsetime( m s)Product
Length(mm)LSA200160.5~8m26mm163205.1325LSA20024244807.1485LSA20032326409.1645LSA200404080011.3805LSA200484896013.4965LSA2005656112015.51125LSA2006464128017.61285LSA2007272144019.71445LSA2008080160021.81605LSA2008888176023.91765LSA2009696192026.01925
Dimension and wiring Certifications Packaging &
ShippingDiagnostic function1. Self-failure test functionWhen
the power is on (within 2 seconds), the light curtain carries out a
self-test to confirm whether there is a fault. In addition, a
self-test will be performed periodically (within response
time) during the work process.2. Control
output(OSSD)waveformWhen the light curtain is in the lighting
state( the beams are not blocked), the control output is NO,
while in order to test the output circuit, the Control output
will turn to OFF Periodically and the output circuit is
diagnosed as normal if the OFF signal was feedback. When the
off-pulse signal is not included in the output signal, the output
circuit or wiring of the receiver is diagnosed as a fault, and the
light curtain immediately enters the locking state. Product
self-inspection steps1. Detect whether the installation position of
the object and the proximity sensor has deviated, slacked, or
skewed; whether there is slack, poor contact, or disconnection in
the wiring and connection parts2. Whether there is adhesion or
accumulation of metal dust, etc.3. Is there any abnormality in
using temperature conditions and environmental conditions?4. Set
whether the flashing of the display lamp type is abnormal.If you
must be careful not to disassemble and repair by yourself during
the inspection, and to easily find out the fault, you can
investigate the operating state of the sensor
Related products about High Quality Infrared Light Curtain for Security Alarm System
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup