Product overview PCM260H Submersible Level Transmitter
accurately measures static pressure of the liquid proportional to
the level depth using high performance piezoresistive diffused
silicon pressure sensor as the measuring element. The result is
converted to standard current signal output through signal
conditioning circuit, establishing the linear corresponding
relation between the output signal and liquid depth to complete the
measurement of the liquid depth. The product has advantages of high
precision and small volume. Submerse it directly into liquid, the
height between the end of the transmitter to the liquid surface is
measured easily. The product is applicable to the measurement and
control of the liquid level in the petroleum, chemical industry,
power plant, urban water supply and hydrological exploration fields
FeaturesPiezoresistive diffused silicon pressure sensorProbe
insertion measurement method, easy to installFor level
measurementMultiple protective structure design, high protection
abilityLCD optionVariety of styles, suitable for various industrial
applicationsAnti-corrosion stainless steel material adopted,
suitable for many occasionsApplicationsWater level measurement in
rivers and lakes Level measurement of containers and storage
systems Sewage lift pump and pumping station control Sewage,
sediment and flood drainage system monitoring Telecommunications
equipment,Diesel generator Performance
parameters Pressure range0~0.5m…20m…200m H2OSupply &
output4~20mA (18~36V, 24V typical)4~20mA with display (12~36V, 24V
typical)1~5V, 0~5V, 0.5~4.5V, 0~10V (12~32V, 24V typical)Operating
temp.-20ºC~85ºCMedium temp.-10ºC~70ºCStorage
temp.-40ºC~125ºCCompensated temp.0m~10m H2O:
0ºC~60ºC10m~200m H2O: -10ºC~70ºCZero temp. coefficient±1.5%FS
(within compensated temp.)Span temp. coefficient±1.5%FS (within
compensated temp.)Overpressure200%FS~300%FSMechanical vibration20g
(20~5000HZ)Shock100g
(11ms)Accuracy0.5%FSInsulation100MΩ/250VDCResponse time≤1ms (Up to
90%FS)Long term stability±0.2%FS/year
ProtectionIP68MaterialLow copper aluminum alloy for junction box;
stainless steel for level probePolyurethane wire for cableMedium
compatibilityAll kinds of media compatible with stainless steel
304 Electrical connection Wiring
method Installation instructions (for reference
only) 1.Installation in still water (deep wells, pools, liquid
tanks, etc.)Installation tips:1) When measuring the level of
stationary fluid in an open container, place the level transmitter
vertically into the bottom of the container and secure the cable
connecting the transmitter to the junction box at the opening of
the container.2) When the medium viscosity is relatively large
(such as sewage pool), casing or bracket can be installed to ensure
that the transmitter can be put into the bottom of the container.3)
When doing an open-air installation, the terminal box of the
transmitter should be placed in a ventilated and dry place to avoid
direct exposure to light and rain, which may cause the shell
temperature to be too high or water to get inside and damage the
internal circuit board.2. Installation in moving water (rivers,
lakes, etc.)Installation tips:1) When measuring the water level in
flowing water, when the medium fluctuates greatly, a steel pipe can
be inserted in the water channel with an inner diameter of about 50
cm. Make several holes of about Φ5 in diameter on the side of the
immersed pipe opposite to the flow direction to allow water to
enter the pipe and fix the cable and junction box at the outlet of
the pipe.2) When the medium of the water channel fluctuates greatly
or the sediment is large, a damping device can be installed to
filter the sediment, eliminate the adverse effects of dynamic
pressure and wave and ensure the measurement accuracy.3) When
installing the product in lightening intensified area, please
indicate "Lightning Protection" when placing an order. Meanwhile,
it is recommended that users install lightning protection devices
at the site and ensure that the product and power supply are
reliably grounded to reduce damage to the transmitter caused by
lightning. Pressure range selection Pressure range
codePressure referencePressure rangeOverpressureBurst
pressureRemark0.5miG0.5m H2O300%FS600%FS 1miG1m
H2O300%FS600%FS 1.5miG1.5m H2O300%FS600%FS 2miG2m
H2O300%FS600%FS 2.5miG2.5m H2O300%FS600%FS 3miG3m
H2O300%FS600%FS 3.5miG3.5m H2O300%FS600%FS 4miG4m
H2O300%FS600%FS 4.5miG4.5m H2O300%FS600%FS 5miG5m
H2O300%FS600%FS 5.5miG5.5m H2O300%FS600%FS 6miG6m
H2O300%FS600%FS 6.5miG6.5m H2O300%FS600%FS 7miG7m
H2O300%FS600%FS 8miG8m H2O300%FS600%FS 9miG9m
H2O300%FS600%FS 10miG10m H2O200%FS500%FS 12miG12m
H2O200%FS500%FS 15miG15m H2O200%FS500%FS 18miG18m
H2O200%FS500%FS 20miG20m H2O200%FS500%FS Cable
length selection Pressure range codeMapping
relationCodeDefinition0.5miL1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20
L25L1.5Cable length 1.5m1miL1.5 L2 L3 L5 L6 L8 L10 L12 L15 L18 L20
L25L2Cable length 2m1.5miL2 L3 L5 L6 L8 L10
Related products about Wtsensor PCM260h CE Piezoresistive Silicon Water Tank Level Measurement Sensor
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup