Hanna Hi9829 Professional Multi-Parameter Measuring Device for pH, Conductivity, Do, ISE, Turbidity, GPS Opt

HANNA HI9829 Professional Multi-parameter Measuring Device for pH, conductivity, DO, ISE, turbidity, GPS optISE ELECTRODE METER SPECIFICATIONpH Range: 0.00 to 14.00 pHpH Accuracy: (@25ºC/77ºF) ±0.02 pHpH Calibration: automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffermV Range: ±600.0 mVmV Accuracy: ±0.5 mVORP Range: ±2000 mVORP Resolution: 0.1 mVORP Calibration: automatic at one custom point (relative mV)EC Range: 0 to 200 mS/cm (absolute EC up to 400 mS/cm)EC Accuracy: ±1% of reading or ±1 µS/cm whichever is greater EC Calibration: automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom pointTDS Range 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor)TDS Accuracy: ±1% of reading or ±1 ppm (mg/L), whichever is greaterResistivity Range: 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cmResistivity Resolution: dependent on resistivity readingesistivity Calibration: based on conductivity calibrationalinity Range: 0.00 to 70.00 PSUSalinity Resolution: 0.01 PSUSalinity Accuracy: ±2% of reading or ±0.01 PSU whichever is greaterSeawater σ Range: 0.0 to 50.0 σt, σ, σSeawater σ Resolution 0.1 σt, σ, σ Ammonium-Nitrogen Range 0.02 to 200.0 ppm Am (as NH4 +-N)Ammonium-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppmAmmonium-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppmChloride Range 0.6 to 2 00.0 ppm Cl (as Cl- )Chloride Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppmChloride Calibration 1 or 2 point, 10 ppm and 100 ppmNitrate-Nitrogen Range 0.62 to 200.0 ppm Ni (as NO3 - -N)Nitrate-Nitrogen Resolution 0.01 ppm to 1 ppm 0.1 ppm to 200 ppmNitrate-Nitrogen Calibration 1 or 2 point, 10 ppm and 100 ppmTurbidity Range 0.0 to 99.9 FNU; 100 to 1000 FNUTurbidity Resolution 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNUTurbidity Accuracy ±0.3 FNU or ±2 % of reading, whichever is greater Turbidity Calibration Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or customDO Range 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L)DO Resolution 0.1%; 0.01 ppm (mg/L)DO Calibration automatic one or two points at 0 and 100% or one custom pointAtmospheric Pressure Range 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPaAtmospheric Pressure Resolution 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa Temperature Range -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 KTemperature Accuracy ±0.15 °C; ±0.27 °F; ±0.15 KTemperature Calibration automatic at one custom pointTemperature Compensation automatic from -5 to 55 °C (23 to 131 °F)Logging Memory 44,000 records (continuous logging or log-on-demand of all parameters)PC Connectivity USB (with software)Battery Type/Life 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configurationGPS 12 channel receiver 10 m (30 ft) accuracyN:B The supply should include, hard carrying case, DC adapter, probe maintenance kit, PC application software, USB cable (PC to meter), power supply cable, cigarette lighter power cable, quick calibration solution, Button with holder (5), 1 pH/ORP sensor, 2 galvanic DO sensor, EC sensor, short calibration beaker, short protective weighted shield, NiMH rechargeable "C" cell batteries (4), 12VDC power adapter, and instruction manual, EC/turbidity sensor, long calibration beaker and long protective weighted shield in place of the EC sensor, turbidity calibration solutions (230 ml); 0 FNU, 20 FNU, and 200 FNU.2yrs Warranty.Related RecommendsCompany InformationFAQ> if the machine broke after a period of use, can I return it back and get a refund?iClear HealthCare has a secure procedure to do the product return and repair, please check our servicepolicy for more information. > I have NO experience buying medical stuff in China. Is the quality good?There are multiple options in China for medical equipment, iClear HealthCare aims to provide high-quality products at a competitive price. > How long will it take to reach me after the payment?By Express, it takes 5-7 working days to arrive;By Air, 3-4 days to the international airport;By Sea, around 25-55 days to the seaport. >> Can you help set up a clinic or provide complete equipment for hospital projects?We have a series of complete solutions for clinics and hospital equipment setup. iClear HealthCare has helped set up several clinics and 2 hospitals in East Asia, African, and Saudi and supply all the medical equipment. These projects have saved a lot of time, money, and energy for our customers.  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1