Product DescriptionResidual Current RelayGeneralASJ Series of action relay of after-current, low-voltage circuit break or low-voltage contactor can be made up for combined after-current production device, which is mainly applied for the TT and TN system distributing circuit with the alternating current 50Hz, the rated voltage 400V or below. ASJ Series of action relay of after-current is applied in the earth fault protection for the electric circuit, so as to prevent the equipment damage and the fire accident of electric equipment caused by the ground fault current, moreover, it also can provide indirect contact protection against the electric shock risk.Features1. The measurement of A-type after-current;2. The streamer display of current percentage;3.The setting of rated residual action current;4. The setting of non-driving time of limitation;5. Two-pair relay output;6. Possessing the function of on-the-spot and long-distance testing and resetting.TypesTypesBasic functionInstalling wayASJ10-LD1 CMeasurement of AC-type after-current;Indicator of current off-limit alarm; The setting of rated residual action current ( see in the table 2);The setting of non-driving time of limitation ( see in the table 2);Two-pair relay output;Possessing the function of on-the-spot and long-distance testing  and resettingrail guiding (TS35mm)ASJ10-LD1 AThe measurement of A-type after-current;The streamer display of current percentage;The setting of rated residual action current ( see in the table 2);The setting of non-driving time of limitation ( see in the table 2);Two- pair relay output(both of which can be set) *;Possessing the function of on-the-spot and long-distance testing  and resettingASJ20-LD1 CMeasurement of AC-typeafter-current;Indicator of current off-limit alarm;The setting of rated residual actioncurrent ( see in the table 2);The setting of non-driving time of limitation ( see in the table 2);Two- pair relay output;Possessing the function of on-the-spotand long-distance testing andresettingScreenstructure (48square)ASJ20-LD1 AThe measurement of A-type after-current;The streamer display of currentpercentage;The setting of rated residual actioncurrent ( see in the table 2);The setting of non-driving time oflimitation ( see in the table 2);Two- pair relay output(both of whichcan be set) *;Possessing the function of on-the-spotand long-distance testing andresetting  Technical ParametersTechnical parameterIndex Type ACType AinputRated residual action current I△n0.03,0.1,0.3,0.5(A)0.03,0.05,0.1,0.3,0.5,1,3,5,10,30(A)Non-driving time of limitation △t0.1,0.5(s)0,0.06,0.1,0.2,0.3,0.5,0.8,1,4,10(s)Rated residualnon-action current I△no50%I△n50%I△nperformance characteristicssimple sinusoidal alternating currentsimple sinusoidal alternating current and pulsating direct currentfrequency50Hz±5Hz50Hz±5Hzaction error-20% ~ -10%I△n-20% ~ -10%I△noutputoutput modeone is the normal closing and the otherone is the normal closing or opening, and the other is for the transformation  is for the transformation contact capacity5A 250VAC 5A30VDCAL1:8A 250VAC 5A 30VDC AL2:6A 250VAC 5A 30VDCreset modethe on-the-spot one and the long-distance one,the on-the-spot one, the long-distance one and the automatic onepower supplyvoltage rangeAC110V,AC220V(permissibleerror±10%)AC110V,AC220V,DC85-270V(permissible error±10%)power dissipation≤5Wpower frequency withstand voltageThe effective value of alternating current between the power supply, input and output: 2kV/1minunder the normal operationtemperatureoperating temperature: -20ºC ~ +55ºC storage temperature: -30ºC ~ +70ºChumidity≤95%RH, with moisture condensation, and corrosive gas placeheight above sea level≤2000mclass of pollutionGrade threeinstallation categoryType ThreeDimension(Unit:mm)  instrument typePanel size (mm)Shell size (mm)hole size(mm)ASJ20-LD1C ASJ20-LD1A48×48( width by height)43.8×43.8×100(width byheight by depth)45×45(width byheight)ASJ10-LD1C ASJ10-LD1A85×54×64(length by width by height)Typical ConnectionQuotation  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1