12kv Efficient High Voltage Vacuum Contactor-Fuse Combination Switch for Switchgear

General descriptionGet ready to experience the power of VACYC permanent magnet AC M.V. vacuum contactor and VACFC series AC M.V. vacuum contactor-fuse combination apparatus (F-C)! These three-phase AC indoor middle voltage switch devices are perfect for AC 50-60Hz and have a rated working voltage of 7.2kV and 12kV. With their flexible function combination, compact and reliable structure, multiple protection functions, long service life, and frequent operation capabilities, these devices are the ultimate solution for opening and closing load circuits such as AC motors and transformers. Plus, they can also be used for capacitor reactive power compensation.The VACFC series combination apparatus features a modular combination structure that can be used by a single contactor or combined into F-C. It can be fixed or drawout moving type, and the drawout type can be used with KYN28A(GZS1) intermediate cabinet with a width of 650mm or 800mm. It's the perfect replacement for VSC/P contactor.The VACFC contactor can be used alone or with other electrical apparatus. And with our 12kv Efficient High Voltage Vacuum Contactor-Fuse Combination Switch for Switchgear, you'll get the ultimate performance and reliability. So, what are you waiting for? Experience the power of VACYC and VACFC today!Normal using conditionsa. Environment temperature: -5ºC~+40ºC, and the average value is no more than +35ºC within 24 hours.b. Altitude: no more than 1000m.c. Atmospheric conditions: monthly highest humidity in the wettest month is no more than 90% and the monthly average minimum temperature shall be 25ºC. Condensation on the products due to temperature changes shall be considered.d. Impact vibration: The place is without extensive shaking, impact, and vibration.e. The place is without explosion hazards, enchant gas, and sleet.f. No rain and snow in placesg. Pollution degree: Three gradeh. Installation type: IIIi. Installation condition: The slant angle between the installation surface and the vertical surface is no more than 15°.Main technical parameter ItemUnitVACYCVACFCRated voltagekV127.2127.2Rated currentA40025-16025-315Rated breaking currentkA3.240Rated making currentkA4-Limit breaking capacitykA4.540(100peak value)4s rated short time withstand currentkA4-Peak withstand currentkA10-1s overload withstand currentkA6-Rated transfer currentkA-3.151 min rated power frequency withstand voltagekV42324232Lightning impulse withstand voltagekV75607560Power frequency withstand voltage of control circuitkV22Rated operating voltageV220V(AC/DC optional)Operating voltage rangeV75%-100% UeMaximum operating currentA