(SC(B)-10) 12kv Resin Insulation Dry-Type Power Transformer

SC(B)-10  Dry-type Power TransformerNormal operation condition Altitude      < 1000 m IndoorMax. Ambinet temperature     +40ºCMax. Daily average temperature       + 30ºCMax. annual average temperature    +20ºCMin. temperature  -5ºCSupply transformers operate under special conditions according to customer requirements.Features 1. The core is made of cold rolled grained high-oriented silicon steel sheets  that thickness ≤0.3mm with 45 degree mitred joints. The surface is coated with special resin for moisture and rust proof.2. Normally the LV winding materials is copper foil cylinder type excepet for small capacity transformers which LV winding materials is copper wire; The HV winding structure is multi-layer cylinder type that has good ampere-turn balance, low leakage flux, high mechanical strength and strong short-circuit withstand capability.3. By installing the low noise fans that controled by the temperature control device,the operation capacity of the transformer can be increased by 40%.4. The temperature device which sensers buried in LV winding can control the fans or send alarm & trip signals to protect the transformer.5. The transformer can be installed in a enclosure which protetion class is IP20 or IP23, the enclosure can prevent small animals coming inside the transformer to avoid short circuit, and also safeguard the personal safety.6. Sc(b)9      No-load losses Equal To Standard Value In GB/T10228-2008                    No-load losses Equal To Tagged Value In GB/T10228-2008    Sc(b)10   No-load losses Decrease By 10% Compared with Standard Value In GB/T10228-2008                    No-load losses Decrease By 5% Compared with Tagged Value  In GB/T10228-2008Technical Data6KV 10KV main 30kVA~2500KVA NLTC distribution transformerNominalcapacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV) High voltage taprange F class(120ºC)H class(120ºC)3066.36.61010.511 ±2×2.5% or  ± 5% 0.4 Yyn0   orDyn11 1907107602.04.0 50270100010702.080370138014801.5100400157016901.5125470185019801.3160540213022801.3200620253027101.1250720276029601.1315880347037301.0400980399042801.05001160488052301.06301340588062900.856301300596064000.856.08001520696074600.8510001770813087600.85125020909690103000.851600245011700125000.852000305014400155000.702500360017100184000.701600245012900139000.858.02000305015900171000.702500360018800202000.706KV 10KV main 315kVA~2500KVA NLTC Power transformerNominalcapacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV) High voltage taprange F class(120ºC)H class(120ºC)63066.36.61010.511 ±2×2.5% or  ± 5% 33.1566.3 Yyn0   orDyn11 1440636068001.04.0 8001620760081301.010001940878093900.851250234010400111000.851600279012700136000.852000360015200162000.702500423017800191000.703150504020900223000.6040001010.511603025100269000.606.05000720029700318000.506300850035300378000.506KV 10KV main 630kVA~6300KVA OLTC distribution transformerNominalcapacity(KVA)Voltage unitcombinationLow voltage(KV)Vector GroupNo-load loss(W)Loasloss (W)No-load current(%)Short-circuit impedance(%)High voltage(KV) High voltage taprange F class(120ºC)H class(120ºC)31566.36.61010.511 ±4×2.5%  0.4 Yyn0Dyn11 990361038601.14.0 4001120427045701.15001290522055801.16301490617066001.06301440636068001.06.08001710750080201.010001980878093900.851250234010400111000.851600272012400133000.852000342015200162000.702500396018100194000.70Note: The physical dimension in the manual is only provided for design reference, and the fimal dimension shall be based on the actual outline drawing.   /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1