2000kVA Cast Resin Distribution Power Dry Type Transformer

SCE vacuum cast resin transformers in this size range from 10kVA to 10000kVA are used to step down three-phase medium voltage to low voltage for power distribution. These transformers are used primarily in metropolitan areas (public buildings, offices, distribution substations) and are also found in industrial applications. Core The magnetic core has a miter step-lap joint to ensure optimum performance and minimum sound levels. The magnetic steel is cut to length in a sequential way and automatically stacked, ensuring dimensional accuracy and single sheet interlacing within the full stack. Windings The high voltage winding has a continuous drop down disc with an aluminum strip conductor and double layer insulation. Windings are casted under vacuum with epoxy resin. Transient analysis test has been performed to verify the electrical stress distribution through the windings confirming the highest strength of our design. The low voltage winding is made of copper or aluminum foil, and insulating foil pre-impregnated with resin. After the winding process, the coil is cured into an oven resulting in an extremely compact winding which can withstand the dynamic stresses produced by short-circuit. Accessories All the accessories needed to customize our products to your needs. The enclosures are made of bolts on steel sheets with removable panels to access connections and tapings. Finishing can be galvanized, painted, depending on the application and your requirements. The design has been optimized in order to secure the requested cooling of the transformer for all levels of protection degree. Enclosures can be shipped assembled on the transformer or flat packed for assembly on site. Other accessories Cooling fans. Temperature monitoring unit( Thermal control system) Locking device (available on request) Test Transformer ratio and connection Measurement of load losses and short circuit impedance. Measurement of no-load losses. Separate source withstand voltage test Induced over-voltage test Temperature rise test Lighting impulse withstand voltage test Measurement of partial discharge Other transformers like rectifier transformer are also available on request. Parameters of  SCB9-Z series 10kV non-excited tap changing low noise dry-type transformer(Vector group: Yyn0 or Dyn11)TypeRated  voltageNo-load lossLoad    lossNo-load currentImpedance    voltageNoise  levelWeightDimensionsmmHVTapping    rangeLV(120° C)kV%kVWW%%dBkgML× W× H SCB9-Z-30/1066.36.61010.511± 5or± 2× 2.50.41907202.2446420 1010× 740× 940SCB9-Z-50/1027010502490 1060× 740× 975SCB9-Z-80/1037014601.85805501110× 740× 1000SCB9-Z-100/1040016701.8700 1130× 740× 1060SCB9-Z-125/1047019501.647820 1180× 740× 1090SCB9-Z-160/1054022501.6930 1210× 740× 1100SCB9-Z-200/1662026701.61080 1240× 740× 1170SCB9-Z-250/1072029201.61280 1290× 740× 1215SCB9-Z-315/1088036701.4481460 1360× 840× 1245SCB9-Z-400/1098042201.41700 1410× 840× 1280SCB9-Z-500/10116051701.419806601450× 840× 1380SCB9-Z-630/10134062201.2492250 1530× 840× 1400SCB9-Z-630/10130063101.262250 1530× 840× 1440SCB9-Z-800/10152073601.22700 1590× 940× 1550SCB9-Z-1000/101770860013210 1650× 940× 1630SCB9-Z-1250/1020901026015136508201740× 940× 1690SCB9-Z-1600/1024501242014450 1770× 940× 1860SCB9-Z-2000/103320153000.8535160 1900× 940× 1960SCB9-Z-2500/104000181800.86100 2010× 940× 2030    /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1