Power TransformerPower transformers are a core component of power
transmission system. The substation transformer used for power
transmission and transformation in a unit or substation, and is
also the core part of the substation. Transformers are the core
equipment of the traction power supply system of electric
locomotives, and also the key equipment to ensure the safe and
stable operation of the traction power supply
system. Product DescriptionDesign and Manufacture
Standard ANSI-IEEE 57. 12/CSA/EN/BS/GOST/AS,IEC 600761
DesignSealed-tank system /Inert-gas pressure system or Conservator-tank system without diaphragmOn load or no load voltage tap changer ONAN/ONAF/ODAF/OFAF/OFWF/KNAN/KNAF Insulation Mineral Oil Inhibited I Not Inhibited I Vegetable oil Primary voltage Up to 230kv, up to 900kv BIL Capacity Up to 240MVA Frequency 50/60 HZOperating
ConditionSuitable for indoor and outdoor application. Ambient
temperature:-50 ºC~40 ºCRelative humidity:ambient air relative
humidity should be below93%,Altitude:≤1000mMax wind speed:≤35
m/sEarthquake acceleration:horizontal acceleration ≤0.3g
vertical acceleration≤0. 15gSpecial conditions:customized
products are available.STANDARD FEATURESCapacity range:Through 60
MVA (ONAN), with high-voltage ratings through 230 kV (900 kV
BIL)Service Location: OutdoorCore: Regular grain-oriented; mitered
cruciform with step-lap constructionCoils: Cylindrical
construction; all copper windings, custom tempered per design
requirements; circular windings with rectangular or
continuously-transposed conductor; helical low-voltage
windings; continuous disc medium-voltage windings;
shielded disc high-vollage windingsRadiators: Detachable panel type
with shut-off valves; mild steelInsulating oil: mineral oil type
I & typellTank Cover.Welded, Bolted Manholes: On
cover or tankTank Base: Flat bottom or Skid under baseTank
Material: Mid SteelFrequency: 60
Hertz Winding Tem rise: 55 ºCHV Taps; DETC,
ETC in tank or out- Above rated volts: 2 x2- 1/2% off load taps of
full capacity -Below rated volts: 2 x 2- 1/2% off load
laps of full capacityValve: Drain and Fiter Valves, w/Sampler
Lifting, Moving,
and Jacking FacilitiesTechnical DataTechnical Data for 69KV Class
Three Phase Two Winding OLTC Power Transformer(KVA)Rated
Power (KV)High Voltage(KV)Low VoltageConnection SymbolShort
CircuitImpendence (%)No-load Loss (KW)On-load Loss (KW)No load
Current
(%)10000696.36.610.511YNd11912.147.60.751200012.656.50.531500015.169.50.492000017.984.20.492500021.199.50.423000025.11200.423750030140.30.395000035.4174.30.396000042.12100.39Technical
Data for 69KV Class Three Phase Two Winding NLTC Power
Transformer(KVA)Rated Power (KV)High Voltage(KV)Low
VoltageConnection SymbolShort CircuitImpendence (%)No-load Loss
(KW)On-load Loss (KW)No load Current
(%)10000696.36.610.511YNd11911.647.60.751200013.656.50.531500016.369.50.492000019.284.20.492500022.699.50.423000026.81200.423750031.9140.30.395000038.6174.30.396000044.42100.39Technical
Data for 115KV Class Three Phase Two Winding OLTC Power
Transformer (KVA)Rated Power (KV)High Voltage(KV)Low
VoltageConnection SymbolShort CircuitImpendence (%)No-load Loss
(KW)On-load Loss (KW)No load Current
(%)100001151381616.36.610.511YNd1110.511.851.20.821200013.759.50.821500016.373.10.762000019.588.40.762500022.71050.693000027.41260.693750032.91480.635000038.91840.636000046.42210.57Technical
Data for 115KV Class Three Phase Two Winding NLTC Power
Transformer (KVA)Rated Power (KV)High Voltage(KV)Low
VoltageConnection SymbolShort CircuitImpendence (%)No-load Loss
(KW)On-load Loss (KW)No load Current
(%)100001151381616.36.610.511YNd1110.510.550.20.641200012.459.50.64150001573.10.592000017.888.40.5925000211050.5430000251260.543750029.91480.565000035.3178.50.526000041.92210.48Technical
Data for 230KV Class Three Phase Two Winding OLTC Power
Transformer (KVA)Rated Power (KV)High Voltage(KV)Low
VoltageConnection SymbolShort CircuitImpendence (%)No-load Loss
(KW)On-load Loss (KW)No load Current
(%)300002306.36.610.51134.566YNd1112301280.6937500361490.6350000431800.6360000502090.57Technical
Data for 230KV Class Three Phase Two Winding NLTC Power
Transformer (KVA)Rated Power (KV)High Voltage(KV)Low
VoltageConnection SymbolShort CircuitImpendence (%)No-load Loss
(KW)On-load Loss (KW)No load Current
(%)300002306.36.610.51134.566YNd1112281280.737500331490.750000391800.6560000462090.65Transformer
TestWinding resistanceWinding insulation resistanceCore insulation resistanceRatioPolarity
and phase relationInsulation power factorControl(auxiliary) cooling
lossesSingle-phase excitation testsNoload losses and excitation
currentImpedance voltage and load lossesZero-phase
sequence impedance voltageTemperature
riseLow frequency dielectric testsLow frequency dielectric tests on
axiliary devicescontrol, and current transformer circuitsLightning
impulseFront of wave impulseSwithing impulsePartial
dischargeAudible sound levelOperati
Related products about 25 30 40 50 100 250 Mva Power Transformer Price
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup