HOW TO ENTER THE SETTINGSSet prefixSetting descriptionC1Pressure calibration setting, the minimum value is 0, the maximum value is 2.0, and the default initial value is 1.0. Correct the current displayed pressure valueC2The minimum value of water shortage pressure threshold is 0, the maximum value is 1.0, and the default initial value is 0.5. When the water pressure isower than this value for a long time (the time is set by the water shortage time), the water shortage faulf is reported.C3The minimum value of water shortage time is 1, the maximum value is 5, the default initial value is 3, and the unit is minuteC4Start the pressure proportional setting, the minimum value is 50, the maximum yalue is 90, and the default initial value is 70.When the actual water pressure islower than(set pressure" starting pressure ratio), the water pump starts automaticallyC5Detect the setting of the high temperature alarm switch of water temperature.0 is off 1is anC6Set the
high temperature alarm threshold of water temperature. The minimum value is 25, the maximum value is 80, and the default initial value is 70.When the water temperature is higher than this temperature threshold, the alarm of high water temperature is reported.C7Detect the setting of low temperature alarm switch of water temperature.0 is oft.1 is onC8Adjust the upper limit of set pressure, maximum 8.0C9Automatic pressure drop detection switch to prevent the water outlet fromslowly closing without shutdown due to pressure fluctuation,The default is on, 0 is off, and 1 is on.CAThe smaller the pressure difference is, the less obvious the pressure drop is.However, it may lead to the slow closing of the water outlet without shutdown,and vice versa. The default value is 10, the minimum value is 5. and the maximum value is 20CbThe module temperature threshold value is used to adjust the upper limit of power according to the module temperature. The setting range is 0,65~80.0 means to turn off this function. The default value is 65CCThe main switch of water flow switch, with a range of 0~1, where 0 means closed, 1 means open, and the default is 1.F1~F4The motor parameters are not adjustable by the user.TROUBLESHOOTINGFault display Show codeFault detection methodCause offailureTroubleshootingE01Voltage too lowMeasure the incoming ine woltage of thefrequengy converterThe incoming linevoltage of frequencyconverter is lowerthan 140V1.Add a voltage regulator to the powersupply2. When the power sugply voltageecovers to above 150W the fault will becleared automatically and the water pump will work normally; A regulated power supply is provided for thespedial feed pump;E02Vollage too highMeasure the incoming line voltage of thefrequency converterThe incoming linevoltage of freguency converter is higherthan 260V1.Add a voltage regulator to the power supply2.When the power supply voltage recovers to below 260V the fault will be deaned automaticaly and the water pumo wiwork normally; A regulated power supply s provided for the special feed pump:E03Sensor fault1.Plug and unplug the sensor signal wire to observe whether the alarm is eliminated;2.Observe the pressure change of the water ump
duringemergengy startup operationPoor contact between sensor and signal wireTurn off the power and plug the signal cable again Abnormal sensorReplace the sensorE04The controller temperature is too nighCheck whether thetemperature af thecontroller heat sink is greater than 901.The controllertemperature is too high2. The installation position of water pump is not ventilated; Poor contac
ot radiator:1.Wait for natural cooling2. Install the water pump at theventilated place to dissipate heat Check the radiator contact;E08Motor startfailedThis fault still occursmany times after the fault s cleared automaticaily1.The motor cannot bestarted because theimpeller is stuck2. Startup failed1.Take out the water injectioncomponent and observe whetherthere are foreign matters in the pump2.Contact after-sales serviceE09Speed feedbacktailedThis fault still occurs many times after the fault is cleared automaticaily1. The impeller is stuck causing the motor to rotate slowly2. Speed feedback failed1. Take out the water injectioncomponent and observe whetherthere are foreign matters in the pump 2.Contact after-sales serviceE12High watertemperature alarmCheck whether the water temperature is greaterthan the set threshold (70 *by default)The water temperature is greater than the setthreshola1.Wait for natural cooling of watertemperature;2.Increase the high temperaturethreshold of water temperature; Close the high temperature alarm of water emperatureLeakage LED Lightcomes on1.With the tap tumedon,The leakage LED lamp | does not tum oftautomatically2. With the tap turnedon,The leakage LED light goes out automatically.1.The water flowswitch is loose or damaged2.Water pipe leaks.Check whether the
Related products about Permanent Magnet Variable Frequency Centrifugal Pump For Household With ISO (PBG4-30)
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup