Z4-112/4 5.5kw 6kw 7.5kw 440V DC Electric Motor Industrial Motor Brush DC Motor Z4 DC Motor

Basic Info.Model NO.Z4-112/4-1 5.5KW 440VApplicationUniversal, IndustrialOperating Speed Adjust Speed Excitation Mode Excited Function Driving Casing Protection Closed Type Number of Poles1Structure and Working Principle Brush Type Z4 CertificationISO9001, CCCBrandWangpaiEff90%Work SystemContinuous Working SystemAcceleration of MotorSeparated Excited MotorReactive Power5.5kwTrademarkWPDJTransport PackagePlywood CaseOriginYangzhouProduct DescriptionZ4 SeriesDCMotor     Power: 1.4kw - 600KWVoltage: Normal 160V, 400V, 440VSpeed: Rated Speed referenceProtection Degree: IP21SInsulation Class: FDuty: S1Package: Export Wooden PackagePayment: 40% in advance, balance by T/T or L/C at sight Z4-112/4-1, 5.5KW, 440V, 1480~1800r/min, IC06, IP21S, F InsulationTechnical DataMounting DimensionsConstruction1. Mounting and Type of constructionMounting modes comply with the State Standard GB/T997 stipulated as follows:2. Protection and Cooling Method.The basic cooling method of motor is IC06, It means it have a blower for ventilate, also it can be made for IC17, It means use pipe as the cold air inlet, the air outlet is shutter structure. Also it can be made for IC37, it means the cold air's inlet and outlet both use pipe. And it's have many deriving form, such as self-ventilation, axial flow fan type, enclosed type, air-air cooler type, etc. The request for the air flow, blast pressure, power of the air blower, etc of different frame motor please see technical data sheet 1. The protection degree of whole series Z4 motor reaches IP21Sa. For Z4-100 - Z4-160, The blower is mounted on the non-drive side.b. For Z4-180 - Z4-450, The blower is mounted on the drive side.c. The required cooling air volume, air pressure and fan motor capacity are shown below:(Table 1)*All the ventilating fan motors are three phase, two pole, 380V.Motors with the following 5 methods of cooling can also be ordered, but prior consultations are needed.a. Frame size 100 up to 250 may be made into the totally enclosed, frame cooled motor(IC410).b. Frame size 180 up to 250 may be made into the separately ventilated motor with blower mounted on its non-drive side(IC05).c. Frame size 100 up to 200 may be made into self-cooled open motor with its own fan mounted on the shaft(IC01).d. Frame size 160 up to 355 may be made into totally enclosed motor with internal cooling air circulation by independent air-air heat exchanger mounted on it(IC666).e. Frame size 160 up to 450 may be made into totally enclosed motor with independent air-water heat exchanger mounted on it(IC86W). From the drive end(Non-commutator position), The standard terminal box is on the right position of the motor frame. For the request by customer, the terminal box can be made on the opposite position. Also the shaft can be made as double shaft end. The rotor shaft's rotation direction is counter clock-wise viewed from the position of commutator. The driving mode is flexible coupling connection, also can be use for the driving mode have certain radial force(such as belt drive or gear drive), It's allowable radial force should not exceed the value of graph.(see attached B) 3. Accessories for electric motorAccording to customer's request, the motor can be designed to allocate for tacho generator, pulse generator, centrifugal switch, arrester brake and so on.Note: the specification, power and weak-magnet speed range is only for reference, For the refresh of new technologies, new materials, the data of the catalog will be changed accordingly. Electrical performance1, technical data should be used according to the following data work conditions                  A. altitude does not exceed 1000m,B. surrounding air temperature is not more than 40 ° c,C. work environment should not contain acid and alkaline or other to touch with insulation   effect of gas.D. motor for continuous duty (S1),E. motor armature loop and excitation circuitry by static electricity, rectifying power supply by dc generators.F. the series motor performance with GB/T755 the basic technology of motor.2, motor 160V rated voltage is standard, 440V. According to the specific conditions can derive   220V and 400V or other voltage.3, motor rated speed 3,000, 15, 10, 750, 6, 5, 4, 3, 200r/min of nine.To reduce the armature voltage constant torque control, reduce excitation constant power voltage for speed. Speed range of technical data table saw.In the following with rated voltage regulating speed is constant torque. It is no less than the minimum speed regulation 20r/min, still can maintain the rated speed, torque.4, Separate excitation is the basic excitation type of the motors. Nominal field voltage: 180V. Other excitation voltages are also acceptable on request. Forced excitation is allowed with the voltage of less than 500v. When a motor is normally running, its excitation current must not be higher than the rated excitation current.To ensure the reliability of the insulation of excitation system, disconnect excitation circuitry on