8.7/15 (17.5) Kv 500mm2 Copper Aluminum Conductor Single Core XLPE Insulated Unarmored Cable

1 Product StandardThis product is manufactured according to GB/T12706.2, equivalent to IEC60502.2. Or BS, DIN, ICEA standard as customer request.  2 ApplicationThe product is suitable for use in power transmission and distribution lines with rated power frequency voltage 3.6/6kv~26/35kv.3 Operating characteristics- Rated power-frepuency voltage U0/U: 3.6/6kv~26/35kv.- Max.admissible operating temperature of the conductor:90ºC.- Max. short-circurt temperature of conductor shall not exceed 2500C. (5s maximum duration)- The ambient temperature under installation should not below 00C.- The bending radius of a single-core cable should not less than 20 times of the cable diameter. The bending radius of a multi-core cable should not less than 15 times of the cable diameter. 4 Table of the voltage, cores and cross-sectionItemCategory    A ,B3.6/6kV6/10kV8.7/15kV12/20kV18/30kV21/35kVCategory    A ,B6/6kV8.7/10kV12/15kV18/20kV-26/35kVSingle coremm225-120025-120035-120050-120050-120050-1200Three coremm225-40025-40035-40050-40050-40050-400The cable with Category A rated voltage is used in the situation requiring not over 1 min. of grounding fault lasting time. For the cable with Category B rated voltage, the grounding fault lasting time normally is not over 1 hour, max. lasting time is not over 8 hours, annual ground fault lasting time altogether should not be over 125 hours, Category C includes all the system expect Category A and B.5 Type and NameTypeDesignationApplicationsYJVCopper conductor,XLPE insulated,PVC sheathed power cableFor laying indoors,in tunnel or cable trench,unable to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.YJLVAluminum conductor,XLPE insulated,PVC sheathed power cableYJYCopper conductor, XLPE insulated,PE sheathed power cableYJLYAluminum conductor, XLPE insulated,PE sheathed power cableYJV22Copper conductor,XLPE insulated,steel tape armoured,PVC sheathed power cableFor laying indoors,in tunnel in cable trench,or direct in ground,able to bear external mechanical forces.Single core cable is not allowed to laid in magnetic duct.YJLV22Aluminum conductor,XLPE insulated,steel tape armoured,PVC sheathed power cableYJV23Copper conductor,XLPE insulated,steel tape armoured,PE sheathed power cableYJLV23Aluminum conductor,XLPE insulated,steel tape armoured,PE sheathed power cableYJV32Copper conductor,XLPE insulated,steel wire armoured,PVC sheathed power cableFor laying indoors,in tunnel cable trench,well or direct in ground,able to bear external mechanical forces and certain pulling force.YJLV32Aluminum conductor,XLPE insulated,steel wire armoured,PVC sheathed power cableYJV33Copper conductor,XLPE insulated,steel wire armoured,PE sheathed power cableYJLV33Aluminum conductor,XLPE insulated,steel wire armoured,PE sheathed power cable /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1