0.6/1kv Medium and Low Voltage Copper Core PE Insulated PVC Sheathed Electric Power Wire and Cable

Product Description0.6/1kv medium and low voltage copper core PE insulated PVC sheathed electric power wire and cableYJV can be understood in cables as follows: YJ is cross-linked polyethylene insulation; And V represents PVC sheath. Therefore, the full name of YJV is cross-linked polyethylene insulated PVC sheathed power cable. There are also different models in YJV, and different models have different general uses. YJY cable has a simple structure, moderate hardness, and is convenient for transportation, but it does not withstand pressure. Therefore, attention should be paid when storing or transporting. The polyethylene raw material used for YJY cables is more expensive than PVC materials, resulting in a high cost for YJY cables. However, the temperature resistance level of cross-linked polyethylene cables when working is 90 degrees, while the working temperature of PVC cables is only 70 degrees. According to the requirements of some users, YJY power cables can be produced for high demand applications such as flame retardant (ZB), fire resistant (NH), and low smoke and low halogen (WDZ) cables. This type of cable has high safety and practicality, and strong environmental performance. Laying method:YJVYJLV copper (aluminum) core cross-linked polyethylene is laid indoors, in trenches and pipes, and can also be buried in loose soil, but cannot withstand pressure and mechanical external forces.YJV22 YJLV22 copper (aluminum) core cross-linked polyethylene insulated steel tape armored PVC sheathed power cable is laid underground and can withstand mechanical external forces, but cannot withstand large tensile forces.Detailed PhotosThe maximum rated temperature of the cable conductor is 90 ° C, and in case of short circuit (the longest duration shall not exceed 5S).The ambient temperature during cable laying should not be lower than 0 ° C Allowable bending radius during laying: single core cable shall not be less than 15 times the outer diameter of the cable; Multicore cable not less than 10 times the outer diameter of the cable.   modelCopper coremodelAluminum corenameScope of applicationYJVYJY YJLVYJLY Copper or aluminum core cross-linked polyethylene insulated PVC sheathed power cableCopper or aluminum core cross-linked polyethylene insulated polyethylene sheathed power cableWhen laid indoors, in tunnels, cable trenches, and pipelines, or in loose soil, the cable can withstand certain laying traction, but cannot withstand external mechanical forcesYJV22YJY23 YJLV22YJLY23 Copper or aluminum core cross-linked polyethylene insulated steel tape armored PVC sheathed power cableCopper or aluminum core cross-linked polyethylene insulated steel tape armored polyethylene sheathed power cableSuitable for indoor, tunnel, cable trench, and underground direct burial laying. The cable can withstand mechanical external forces, but cannot withstand large tensile forcesYJV32YJY33 YJLV32YJLY33 Copper or aluminum core cross-linked polyethylene insulated fine steel wire armored PVC sheathed power cableCopper or aluminum core cross-linked polyethylene insulated fine steel wire armored polyethylene sheathed power cableSuitable for high drop areas, capable of withstanding external mechanical forces and considerable tensile forces  Product ParametersStructural Dimension Table of Crosslinked Polyethylene Insulated Power Cable(0.6/1kV)order numberSpecificationsConductor structureInsulationCablingInner linerSteel tape armorsheathNumber of cores × Section mm2Number of pieces/diameter mmNominal outer diameter (or fan height) mmNominal thickness mmNominal outer diameter (or fan height) mmNominal outer diameter mmOuter diameter of wrapping mmNominal thickness mmlayer × thick × Width mmNominal outer diameter mmNominal thickness mmNominal outer diameter mYJV YJLVYJV22 YJLV22YJV YJLVYJV22 YJLV2213×2.5+1×1.51/1.781.780.72.87.78.51.02×0.2×2011.31.81.812.114.923×4+1×2.51/2.252.250.73.78.59.31.02×0.2×2012.11.81.812.915.733×6+1×41/2.762.760.74.29.710.51.02×0.2×2013.31.81.814.116.943×10+1×67/1.354.10.75.512.713.51.02×0.2×2516.31.81.817.119.953×16+1×107/1.705.10.76.515.015.81.02×0.2×2518.61.81.819.422.263×25+1×167/2.146.40.98.218.919.71.02×0.2×3022.51.81.823.326.173×35+1×167/2.527.60.99.421.722.51.02×0.2×3025.31.81.926.129.183×50+1×2510/2.527.31.09.321.522.31.02×0.2×3025.11.81.925.928.993×70+1×3514/2.528.71.110.925.226.01.22×0.2×3529.21.92.029.833.2103×95+1×5019/2.5210.21.112.428.629.41.22×0.5×4032.82.02.133.437.0113×120+1×7024/2.5211.51.213.932.132.91.22×0.5×4037.32.22.337.341.9123×150+1×7030/2.5212.01.414.834.235.01.22×0.5×4039.42.22.439.444.2133×185+1×9537/2.5213.41.616.638.339.11.42×0.5×4543.92.42.543.948.9143×240+1×12048/2.5215.41.718.843.444.21.42×0.5×4549.02.52.749.254.4153×300+1×15061/2.5217.01.820.647.648.41.62×0.5×5053.62.72.953.859.4  (pour:YJY  YJLYsameYJV  YJLV,YJV23  YJLV23sameYJV22  YJLV22)Structural Dimension Table of Crosslinked Polyethylene Insulated Power Cable(0.6/1kV)order numberSpecificationsConductor structureInsulationCabling