35kv Copper /Aluminum Conductor XLPE Insulated Power Cable

    Product Description (1).The long-time permissible operation temperture of conductor shall not be higher than 70oC.(2).Conductor maximum short circuit(not more than 5 seconds)temperature shall not be higher than 160 oC.(3).The power cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0 oC.(4).Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents,and flame.(5).Light weight,perfect bending properties,installed and maintained easily and conveniently. 1.Product Performance(1).The long-time permissible operation temperture of conductor shall not be higher than 70oC.(2).Conductor maximum short circuit(not more than 5 seconds)temperature shall not be higher than 160 oC.(3).The power cable is not limited by drop in level when being laid,and the ambient temperature shall not be lower than 0 oC.(4).Perfect chemical stability,resistant against acids,alkalis,grease and organic solvents,and flame.(5).Light weight,perfect bending properties,installed and maintained easily and conveniently.Voltage rating:0.6/1kV3.6/6kV.Conductors:copper or aluminum.Number of cable cores:one core(Single core),two cores(Double cores),three cores,four cores(Four Equal-section-area cores or three equal-section-area cores and one smaller section area neutral core),five cores(Five equal-area cores or three equal-section-area cores and two smaller section area neutral cores).We provide armoured trpe and non-armored type for the power cables above.Our company has been carrying out Chinese national standard GB 12706 and GB 12666.6(equivalent to IEC 60502 and IEC 60331)for PVC insulated power cable and fire resistant cable needed by domestic customer,and for foreign customers we can manufacture in accordance with BS,DIN and other countries,standards.In addition,we can design and manufacture PVC insulated power cable with special characteristics according to needs of customers.Technical Requirements Cu CoreAL CoreDescriptionVVVH-VVVLVNH-VLVCu(Al)Core PVC Insulated PVC Sheathed Power CableCu(Al)Core PVC Insulated PVC Sheathed Fire Resistant CableVYNH-VYVLYNH-VLYCu(Al)Core PVC Insulated PE Sheathed Power CableCu(Al)Core PVC Insulated PE Sheathed Fire Resistant CableVV22NH-VV22VLV22NH-VLV22Cu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Power CableCu(Al)Core PVC Insulated Steel Tape Armored PVC Sheathed Fire Resistant CableVV23NH-VV23VLV23NH-VLV23Cu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Power CableCu(Al)Core PVC Insulated Steel Tape Armored PE Sheathed Fire Resistant CableVV32NH-VV32VLV32NH-VLV32Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Power CableCu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Fire Resistant CableVV33NH-VV33VLV33NH-VLV33Cu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Power CableCu(Al)Core PVC Insulated Fire Steel Wire Armored PE Sheathed Fire Resistant CableVV42VH-VV42VLV42NH-VLV42Cu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Power CableCu(Al)Core PVC Insulated Thick Steel Wire Armored PVC Sheathed Fire Resistant CableVV43VH-VV43VLV43NH-VLV43Cu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Power CableCu(Al)Core PVC Insulated Thick Steel Wire Armored PE Sheathed Fire Resistant Cable Nominal Cross-Section AreaofConductor Core Master Core2.546101625355070951201501853+1Neutral Core1.52.5461016162535507070953+2Neutral Core1.52.5461016162535507070954+1Neutral Core1.52.546101616253550707095 Nominal Thickness of InsulationCross Section(mm2)/KV11.52.546101625355070951201501850.6/10.80.80.811111.21.21.41.41.61.61.82.03.6/6 -----3.43.43.43.43.43.43.43.43.43.4 DC Resistance of Insulation(mm)Nominal section Area(mm2)Resistance not More than(Ω/km)Nominal section Area(mm2)Resistance not More than(Ω/km)Resistance not More than(Ω/km)Nominal section Area(mm2)Resistance not More than(Ω/km) CuAl CuAlCuAl CuAl1.512.118.1250.7271.200.1240.2066300.02830.04692.57.4112.1350.5240.8680.09910.1648000.02210.036944.617.41500.3870.6410.07540.12510000.01760.029163.084.61700.2680.4430.06010.100---101.833.08900.1930.3200.04700.0778---161.151.911200.1530.2530.03660.0605---    Related Product ApplicationOverhead bare conductor has been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers valleys and the places where special geographical features exist.Company InformationJinshui Wire & Cable Groupis located in the national class Zhengzhou high and new technology industries zone in Zhengzhou ,Henan province. We have owned a number of exclusive essential manufacture technologies and has pass ISO 9001 Quality Management System ,ISO 14001 Environmental Management System ,OHSAS18001 occupational Heath Management System ,ISO 10012 Measurement Management System and others from China and a