Power PVC PE XLPE Insulated Copper Electric Insulated Shielded Copper Control Wire Coaxial Rubber AAAC Cable

Power/PVC/PE/XLPE/Copper/Insulated/Copper/Rubber Cableinsulated PVC or PE sheath high voltage power cableThe power cable as one of our main products, the specification and appliance of the power cable are listing as follows: 1.The standardsThe power cable is mainly complying with IEC 60502 standard,  also can be produced according to OEM requirements and other standards, such as BS, DIN, ASTM, VDE, NFC standards, and so on. 2.the construction of the power cable for different voltage grade 2.1 low  voltage  cable power cableLow voltage (0.6/1 kv)single core or multi-corecopper or aluminium conductorpvc inusulationsteel tape armored or galvanized steel wire armored or unarmoredpvc outer sheathpower cable.2.2 medium voltage cabel power cableVoltage grade is up to 35kv,cross-section area can be up to 1000 sqmm  (copper or aluminiun conductor).Conductor long-time  operating temperature is 90 degrees.In short circuit, conductor  highest temperature should be not more than 250 degrees.1kv-35 kv multi-corescopper or aluminium conductorxlpe insulationcopper tape or copper wire screen galvanized steel wire armoredpvc or pe sheathpower cable2.3 high voltage cable power cableHigh voltage (35kv~220kv) copper or aluminium conductorxlpe insulationmetal sheath (lead or corrugated aluminium)hdpe or pvc outer sheath power cable.Laying conditions: for lyaing  under ground with large different  altitude, be able to bear external machanical force and moderate pulling force. 3. the power cable's characteristic:3.1 long time operating temperature for cable conductor is 90 degrees.3.2 the highest temperature of the conductor in short circuit (no longer than 5 seconds) in not more than 250 degrees,if a joint is in the cable, the temperature of the tinning welding joint is not more than 120 degrees, compressing joint not more than 150 degrees and electro-welding joint not more than 250 degrees.3.3 no drop in limited provided there is full mechanical tention when cable is laid. It si forbidden to lay cable in iron-pipe or to fix cable by circling around the cable with iron materials.3.4 being laid, the minimum temperature of the cable shall not be lower than zero degree. In the case of lower temperature, heating measures shall be taken. We can also supply the OEM and customized products according to your request/* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1