0.6/1kv 8.7/15kv Aluminum Conductor PVC/XLPE Insulated Electrical Power Cables

Basic Info.Model NO.YJV,YJV22,YJV23,YJV32,YJV33,YJV42,YJV43,VV,VLVApplicationConstruction, Underground, Power StationVoltageLow and Medium Voltage CableInsulation MaterialXLPESheath MaterialPVCMaterial ShapeRound WireWire Core MaterialCopperCertificationCCC, CE, KemaModelYjv,Yjv22,Yjv23,Yjv32,Yjv33,Yjv42,Yjv43,VV,VlvBrandFar East CableConductorPure 99.99% CopperBrand NameFar East CableFar East CableThe Largest Wire & Cable Manufacturing CompanyMarketing AbilityExceeds 20 Billion YuanQualityGood QualityPriceCompetitive PriceRankRanked Firstly in China Continuously for 18 YearsBrand Value19.869 Billion YuanAward"Famous Trademark of China"Famous"China Famous Brand Product"TrademarkFar East CableSpecificationCE UL KEMAOriginJiangsu, ChinaHS Code8544601300Product Description  Specifications1 IEC, ASTM, DIN, BS standard 2 ISO,CCC,CB certification 3 Factory direct sale 0.6/1kv 8.7/15kv Aluminum Conductor PVC/XLPE Insulated Electrical Power CablesApplicationPVC insulation electric power cable has excellent electrical properties and chemical stability.With simple structure and easy to use,it is suitable for fixed laying AC 50HZ,rated voltage 1kV and below in transmission and distribution lines.Five-core power cable is needed to adapt to the development of distribution system and safety performance,the neutral wire in low voltage distribution systems with the zero line separating the system to run more stable,and ensure the safety of staff.The XLPE insulation power cable has excellent hot-mechanical properties,excellent electrical,chemical resistance properties,also has the advantage of simple structure,light weight,not restricted by the difference of level along the route.Now widely used in urban power grid,mines and chemical plants and other places.Cable insulation adopt XLPE,use chemical method to linear molecules PE into solid nerwork structure of XLPE,thus substantially improving the mechanical properties of PE,and maintaining the superior ellectrical performance.The product is suitable for dynamic line transmission and distribution lines of shielding performance requirements more stringent,especially applies to the rated voltage 0.6/1kV and below frequency inverter control system for power supply or connectiing cables.Frequency conversion cable is actually a shield-type power cable,the difference is that ground wires are divided into third part placed in the three main line between core to uniform electric field and improve levels of electromagnetic radiation of cable.Mostly used in high-power inverter power supply and frequency conversion motor connection.At present nonferrous metal spurt in prices ,copper conductor cost accountion for the cable more than 70% of the total cost of raw materials.In order to guarantee both meet the specification of copper conductor cable,and can significantly reduce the cost of cable.according to market demand .our company has used existing plant equipment. testing equipment,developed the copper clad aluminum composite conductor power cable. Voltage:  0.6/1KV,1.8/3KV, 3.6/6KV ,35kV and below. Standard :IEC 60502-2004 Product Named:1.     The meaning of cable model in letter and number:T....................................Copper conductorL....................................Aluminum conductorYJ..................................XLPEV....................................PVCY....................................PE Armor code:2....................................Double steel tape armor3....................................Thin steel wire armor4....................................Thick steel wire armor6....................................(Double)non-magnetic mental tape armor7....................................Non-magnetic wire armor Oversheath code:2....................................PVC oversheath3....................................PE oversheath4....................................Elastomer oversheath Using Festures of Power Cable:1.Rated Voltage 0.6/1kV PVC Insulation Power Cable :The long-term working temperature of cable conductor should be not more than 70°C. While short-circuit the highest working temperature of cable conductor should be not more than 160°C(5 seconds maximum duration);The minimum bending radius for laying cable(D is diameter):single core unarmoured cable shoule be 20D,multi-core unarmoured cable shoule be 15D,single core armoured cable shoule be 15D,multi-core armoured cable should be 12D;The environment temperature for laying cable should be not less than 0°C. 2. Rated Voltage 0.6/1kV XLPE Insulation Power Cable / Rated Voltage 3.6/6~26/35kV XLPE Insulation Power Cable :The long-term working temperature of cable conductor should be not more than 90°C.While short-circuit the highest working temperature of cable conductor should be not more than 250°C(5 seconds maximum duration); 3. Rated Voltage 0.6/1kV and Freqency Inverter Control System Power Cable :Designed with fully symmetric space structure,cable has excellent electromagnetic compatibility;Low and uniform