Hantek Dso5102p Digital Oscilloscope 100MHz 2 Channels 1gsa/S Real Time Sample Rate USB Osciloscopio

Hantek 2D82 Auto Car Handheld Oscilloscope 4 in 1 Dual Channels Portable Digital Wave Generator Multimeter Automotive DiagnosisDSO5000P SeriesBandwidth:70-200MHz;1GSa/s Real Time Sample Rate;Record length up to 40K; Multiple automatic measurements; Large (7.0-inch) colordisplay, WVGA(800x480);Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.Feature:* 200/100/70MHz bandwidths* 1GSa/s Real Time sample rate* Large (7.0-inch) color display, WVGA(800x480)* Record length up to 40K* Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.* USB host and device connectivity, standard* Multiple automatic measurements* Four math functions, including FFTs standard* Provides software for PC real-time analysis   ModelDSO5202PDSO5102PDSO5072PAcquisitionSample RateReal-Time Sample: 1GS/sEquivalent Sample: 25GS/sAcquisition Modes       NormalNormal data onlyPeak-DetectHigh-frequency and randon glith captureAverageWavefom Average, selectable 4,8,16,32,64,128InputsInputs CouplingAC, DC, GNDInpits Impendance1MΩ±2% II20pF±3pFProbe Attenuation1X, 10XSupported Probe Attenuation Factor1X, 10X, 100X, 1000XMaximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;CAT III: 150VRMS (1×);Installation Category II: derate at 20dB/decade above 100kHz to 13V peak-AC at 3MHz* and above.For non-sinusoidal waveforms, peak-value must be less than 450V.Excursion above 300V should be of less than 100ms duration.RMS signal level including all DC components removed through AC coupling must be limited to 300V.If these values are exceeded, damage to the oscilloscope may occur.HorizontalSample Rate Range500MS/s--1GS/sWaveform Interpolation(sin x)/xRecord Length40 KSEC/DIV Range4ns/div to 40s/div4ns/div to 40s/divSample Rate and±50ppm(at over any ≥1ms time interval)Delay Time AccuracyPosition Range2ns/div to 10ns/div;20ns/div to 80us/div; (-8div x s/div) to 40ms;(-4div x s/div) to 20ms;200us/div to 40s/div; (-8div x s/div) to 400sDelta-Time Measurement AccuracySingle-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);(Full Bandwidth)>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);   Sample interval = s/div ÷ 200VerticalVertical Resolution8-bit resolution, all channel sampled simultaneouslyPosition Range2mV/div to 200mV/div, ±2V200mV/div to 5V/div, ±50VBandwidth100MHz100MHz70MHzRise Time at BNC( typical)3.5ns3.5ns5nsAnalog Bandwidth in Normal and2mV/div to 20mV/div, ±400mV; 50mV/div to 200mV/div, ±2VAverage modes at BNC or with probe, DC Coupled500mV/div to 2V/div, ±40V; 5V/div, ±50VMath+, -, *, /, FFTFFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;1024 sample pointBandwidth Limit20MHzLow Frequency Response (-3db)≤10Hz at BNCDC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;±4% for Normal or Average acquisition mode, 5mV/div to 2mV/divDC Measurement Accuracy,When vertical displacement is-zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected;Average Acquisition ModeWhen vertical displacement is not-zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div];   Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/divVolts Measurement Repeatability,Delta-volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditionsAverage Acquisition ModeTrigger SystemTrigger TypesEdge,Video, Pulse, Slope, Over time, AlternativeTrigger SourceCH1, CH2, EXT, EXT/5, AC LineTrigger ModesAuto, Normal, SingleCoupling TypeDC, AC, Noise Reject, HF Reject, LF RejectTrigger SensitivityDC(CH1,CH2):(Edge-Trigger Type)1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;   DC(EXT):   200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;   DC(EXT/5):   1V from DC to 100MHz;1.75V from 100MHz to 200MHz;   AC: Attenuates signals below 10Hz;   HF Reject: Attenuates signals above 80kHz;   LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHzTrigger Level RangeCH1/CH2: ±8 divisions from center of screen;EXT: ±1.2V;EXT/5:±6VTrigger Level Accuracy( typical)AccuracyCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;is for signals having rise and fall times ≥20nsEXT: ± (6% of setting + 40mV);   EXT/5: ± (6% of setting + 200mV);Set Level to 50%(typical)Operates with input signals ≥50HzVideo Trigger   Video Trigger TypeCH1, CH2: Peak-to-peak amplitude of 2 divisions;EXT: 400mV;EXT/5: 2VSignal Formats and Field Rates, Video Trigger TypeSupports NTSC, PAL and SECAM broadcast systems for any field or any lineHoldoff Range100ns ~ 10sPulse Width Trigger   Pulse Width Trigger ModeTrigger when (< , >, = , or ≠); Positive pulse or Negative pulsePulse Width Trigger PointEqual: The oscilloscope triggers when the trailing-edge of the pulse the trigger level.Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing-edge.Othe