HFM100 Digital Display Hydraulic Application Magnetic Flowmeter

Product Overview:HTM100 Electromagnetic Flowmeter is made of a sensor and a converter. It works base on Faraday's law of electromagnetic induction to measure conductivity of liquid or liquid-solid medium. It requires the conductivity should be greater than 5µS/CM (the conductivity of tap water and raw water is 100-500µS/CM ). It can be used for many mediums like acid, alkali, saline solution, paper pulp, ore pulp etc but the medium can not much conclude ferromagnetic substance or a mass of bubbles. This product is a main flow instrument for measuring conducting liquid, which can be widely used for flow measurement in the fields of water conservancy, municipal administration, chemical, food, pharmacy, papermaking, metallurgy, electric power, environment protection, etc. Features:·Clear LCD display screen, display instantaneous flow and cumulative flow respectively ·Advanced excitation technology, brief excitation circuit with stability and reliability ·Pioneering fuzzy algorithm technology applies to measurement of electromagnetic flowmeter with the performance of artificial intelligence ·Empty and full pipe measurement technique to avoid false alarms ·With low conductivity measurement function ·Prompt response design for high resistance, undistorted collection of weak signals and prompt reaction for flow change , the range rate can achieve 100:1 ·Various optional output communication interfaces Parameters:  Aperture DiameterDN10-DN2400FlangeMeet GB/T9119-2000standard carbon steel (stainless steel optional),other standards can be customizedRated Pressure GradeDN10~DN600, 1.0 1.6 2.5 4.0MPa; DN700~DN2000, 0.6 1.0 1.6MPaLining MaterialChloroprene Rubber (CR), Polytetrafluoroethylene (PTFE), Polyurethane Rubber (PU), Polyethylene (PE), PFA, etc.ElectrodeStainless steel 316L, Hastelloy (HB and HC), Titanium, Ttantalum, PlatinumIngress ProtectionIP68, IP65 for CustomizedAccuracy Grade0.5 gradeMedium TemperatureSensor: -25~180ºC, Transmitter: -10~80ºCMeasuring Flow VelocityLess than 20m/sSupply Voltage24VDC, 220VACOutputCurrent 4~20mA, Pulse, Frequency, RS485, HART, Profibus-PAOrdering Guide:  Item NO.CodeIllustrationHFM100-   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -   -   -     -   -   -   -  -   -   -  -   -    -   -  -   -    -  - -   -    -  -Electromagnetic FlowmeterInstallment WayS -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -   -   -   -  -   -   -  -   -    -   -  -   -    -  - -   -    -  -D -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -   -   -  -  -   -   -  -   -    -   -  -   -    -  - -   -    -  - C -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -   -   --  -   -   -  -   -    -   -  -   -    -  - -   -    -  -Flange TypeCamping TypeInserted TypeInside Nominal Diameter15 -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -    -   -    -    -    -    -   -   -   -  -   -   -  -20 -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -    -   -    -    -    -    -   -   -   -  -   -   -  -                                                                        …2400 -   -   - -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   - -   -    -    -    -    -   -   -   -  -   -   -  -DN15DN20   …DN2400Electrode FormF   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -   -   -   -     -   -    -    -    -    -   -   -   -  -   -   -  -Standard FixationElectrode MaterialS6  -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -    -   -    -    -    -    -   -   -   -  -   -   -  -HC  -   -   -   -   -   -   -   -   -       -   -   -   -   -   -   -   -    -       -    -    -    -    -   -   -   -  -   -   -  -TI  -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -       -    -    -    -    -   -   -   -  -   -   -  -TA  -   -   -   -   -   -   -   -   -    -   -   -   -   -   -   -   -   -    -      -    -    -    -    -   -   -   -  -   -   -  -CW    -   -   -   -   -   -   -  -    -   -   -   -   -   -   -   -   -    -        -    -    -    -    -   -   -   -  -   -   -  -Stainless Steel 316LHastelloy CTitaniumTantalumTungsten carbide ElectrodeLining MaterialCR    -   -   -   -   -    -   -   -   -   -   -   -   -   -     -  -   -   -  -  -   -    -   -   -   -   -  -FE    -   -   -   -   -    -   -   -   -   -   -   -   -   -     -   -  -   -   -  -  - -    -   -   -   -  -PU -   -   -   -   -    -   -   -   -   -   -   -   -   -     -   -  -   -   -  -  -  -    -   -  -   -   -  -Chloroprene RubberPolytetrafluoroethylenePolyurethaneMeasuring Tube MaterialS4     -   -    -   -   -   -   -   -   -   -   -    -   -   -  -  -     -    -   -  -   -   -  -S6     -   -    -   -   -   -   -   -   -   -   -    -   -   -  -  -  -    -   -  -   -   -  -TG     -   -    -   -   -   -   -   -   -   -   -    -   -   -  -  -   -    -   -  -   -