CNC Intelligent ATS Generator Automatic Transfer Switch Electric Manual

CNC Intelligent ATS Generator Automatic Transfer Switch Electric ManualProduct Description1.Ensure un-interruptible service of critical electric powerWhen overvoltage, under-voltage or phase failure occur to a power supply, it will automatically switch over to another power supply or start the electric generator. It is mainly used in hospital, shopping mall, bank, hotel, high buildings and fire control where long time power disconnection is not allowed and ceaseless power supply is needed.2,.Full automatic power supply changeover systemIt is equipped with three changeover methods including self-throwing and self- reset (power network to power network), self-throwing and not self-reset (power network to power network), self-throwing and self-reset (power network to power generation), in order to satisfy different power changeover requirement.3.IntelligentIt has communication interface with built-in RS485, and has two kinds of communication agreement including MODBUS-RUS and electric meter 1997, which can realize real time data upload, distance data configuration and condition monitor, and can achieve the function of telecommand, telemetering, remote control, and remote regulating. Remote vision can be achieved through matching intelligent power distribution system.4.Safe and reliable, and have fire control linkage functionWhen fire disaster occurs to no fire control load, fire protection control center can send signal to intelligent controller, cut off double power supply, ensure fire disaster load to break.Life(N-R-N circle) and Specifications of Automatic Transfer Switch Model numberYCQ9M-63~250YCQ9M-400YCQ9M-630Electrical life (t)100010001000Mechanical life (t)500030002000Total life (t)600040003000Rated dutyuninterrupted dutyUnder-voltage switching setpoint180~210VOver-voltage switching setpoint230~280VContacts switching time≤3sSwitching return delay time0.1~99.9s(Adjustable)Main Technical Parameter of Automatic Transfer Switch SpecificationsExecution breakerRated current (A)Rated voltage (V)Rated impulse withstand voltage (kV)Rated short-circuit making capacity (kA)Rated short-circuit breaking capacity (kA)63M/3PYCM1-63M/3P16/25/32/40/50/63400852.52563M/4PYCM1-63M/4P125M/3PYCM1-100M/3P16/25/32/40/50633063/80/100/125125M/4PYCM1-100M/4P250M/3PYCM1-225M/3P100/125/140/16073.535180/200/225/250250M/4PYCM1-225M/4P400M/3PYCM1-400M/3P225/250/31510550350/400400M/4PYCM1-400M/4P630M/3PYCM1-630M/3P400/500/63010550630M/4PYCM1-630M/4PCompany Profile /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1