5kv 10kv 15kv 20kv 10t Ohm Megger Electrical Testing Meter Megohmmeter Insulation Resistance Tester

5kv 10kv 15kv 20kv 10T ohm Megger electrical testing  meter  Megohmmeter  Insulation Resistance tester 1.Overview      The rapid development of modern industry, the insulation test of high-voltage equipment puts forward higher requirements, and the traditional measurement methods will face severe tests. With the large-scale application practice of optical fiber in intelligent substation, HM2306 10KV insulation resistance tester has good insulation and anti-interference ability, high measurement accuracy, easy miniaturization, and extremely low failure rate, which has received extensive attention. It is widely used  to solve the evaluation of electrical insulation quality of large high-voltage transformers, electric motors, generators, long-distance power cables and tubular busbars under high-voltage substation and power plant on-site strong interference.2.Technical specificationsSafety specifications-IEC 61010-1 CAT.IV 600V pollution level 2-IEC 61326, EMC specification: electrical equipment for testing, control and inspection-IEC60529 IP64 (outer box closed state)The instrument is in line with international safty standards IEC610101:2001.This instrument performs standard Q/WKD10.-Insulation resistance: 50 MW  (between line and shell)-Withstand voltage: AC, 10kV, 50Hz, 1min (measuring line and shell)-Temperature and humidity: -30ºC ~ +60ºC  85%RH-Storage temperature & humidity: -15ºC ~ +55ºC  90%RH-Battery powered: two group battery charging together, 16V lithium ion rechargeable battery 2600mAH ,7.4v 2200mAH or charging side measurement.Power charge:220V±10%,50/60HZ-Size : 38.5. x 29.8. x 19.6.-Weight: 4.5kg-5.7inch screen display, resolution: 320*240-Display mode: digital and analog pointer double display3.Measurement accuracyRated voltage(kV)0.25,0.5,1,2.5,5Measurement voltage(kV)Rated voltage×(1±10%), The load resistance is not less than 1% of the test rangeMinimum error is 5% RDG range(0.001~100)GW/5kV(0.001~200)GW/2.5kV(0.001~50)GW/1kV(0.001~20)GW/0.5kV(0.001~5)GW/0.25kV(0.001~100)GW/10kV(0.001~200)GW/5kV(0.001~200)GW/2.5kV(0.001~100)GW/1kV(0.001~20)GW/0.5kVMaximum error is 10 % RDG range(100~200)GW/5kV(5~10)GW/0.25kV(100~200)GW/10kV (100~200)GW/5kVMaximum error is 20 % RDG range(200~1000)GW/5kV(200~500)GW/2.5kV(100~200)GW/1kV(200~1000)GW/10kV(200~1000)GW/5kV(200~500)GW/2.5kV(100~200)GW/1kVOutput short circuit current≥8mA≥8mAAbsorption ratio,Measurement range of polarization indexMeasurement range: 0.01 ~99.99Maximum error: ±(1%RDG+1d)Measurement range: 0.01 ~99.99Maximum error: ±(1%RDG+1d)Output voltage display error±(3%RDG + 1d)±(3%RDG + 1d)5. Related Products.5. Company profileWuhan Goldhome Hipot Electrical Co.,ltd is an ISO certified factory specially in  manufacture electric test equipment with more than 20 years experience , located in Wuhan city , China .Main products included PD free test set, AC/DC hipot tester, transformer tester, CT/PT analyzer , Circuit breaker tester, relay test set, transformer oil tester ,etc .Warmly welcome to visit Goldhome Hipot factory !  /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1