High Temperature Sensors K Type Thermocouple and Rtd PT100

Product Description High Temperature Sensors K Type Thermocouple PT1001. IntroductionHigh Temperature Thermocouples are specifically designed for durability and reliability in high temperature applications to 4200° F (2315° C). Thermocouple temperature ranges are dependent on element calibration.The probes utilize either Platinum/Rhodium (types R, S, or B) or Tungsten/Rhenium (types G, C, or D) elements, with a variety of insulations and sheath materials.2. Applications: Generally involve oxidizing, reducing, inert gas or contamination atmospheres that challenge the life of the thermocouple.Product Parameters 3.  MEASURING RANGEThe maximum temperature is based on the lowest max. temperature of the element, insulation and sheath material.  CategoryCodeTemperature RangeNi-Cr-Si----Ni-Si-MgN-40° C to 1000° CNi-Cr----Ni-SiK-40° C to 1000° CNi-Cr----Cu-NiE-40° C to 800° CFe----Cu-NiJ-40° C to 750° CCu----Cu-NiT-40° Cto 350° CPt-Rh13----PtR0° C to 1000° CPt-Rh10----PtS600° C to 1600° CPt-Rh30----Pt-Rh6B600° Cto 1700° C4.  B Type Thermocouple Technical Indicators  Conductir MaterialTypeGraduationSpec. of protection tube(mm)Use temperature°CTotal LenghtLength in fluidexternal diameter of ceramic tubeMaterial of protection tubePtRh10-PtWRPS3003504004505506509001150125015020025030040050075010001100φ16φ25High Al content tube0-1300PtRh30-Ptrh6WRRBCorundum tube0-1600PtRh13-pTWRQRφ16φ20High Al content tube0-1200Mini PtRh10-PtWRP-100S252252φ7High Al content tube0-12005. Diagram for example:Detailed Photos 6. Photos for Reference              /* January 22, 2024 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1