Product DescriptionReverse Osmosis(RO) Water Treatment
System MachineIntroductionRO system is widely used in preparation
of water for beverage industry, which features adaptable of
different salt content of water, easy operation, less labor force
and low running cost. Composition of Water Treatment System1.
Pre-treatment SystemPre-treatment system is composed of mechanical
filter, active carbon filter, scale inhibitor and precision filter.
The water temperature requires 25± 30C. Flocculator is used for
destroying electro-neutral of colloid in water, which ensures raw
water can reach to the requirement of Silt Density Index (SDI) ≤ 4.
Mechanical filter can remove most of suspension, colloid and grain
impurity, which can ensure initial purification of water. If some
of raw water comes from tap water, chlorine content maybe is
higher. Low-pressure compound RO membrane has strict limitation to
chlorine and organism, which must be ≤ 0.1mg/1. Because calcium and
magnesium content in raw water is very high, and RO salt-removing
rate is about 97%, which may cause deposit of calcium carbonate,
magnesium carbonate, bitter salt, etc. On concentrated water side.
Deposit adhered on RO membrane surface and may block passage of
components and causes pressure difference increase, water output
decrease and salt-removing rate decrease, which influence normal
running and usage span of RO. So before precision filter, Scale
Inhibitor is equipped to protect and avoids impurity on RO
concentrated water side. 2. RO SystemRO system is composed of
high-pressure pump, RO system and chemical cleaning device. During
running, RO membrane may form some deposit and chemical cleaning
device is equipped for periodical cleaning to ensure stable running
of RO system. This system configures with Dow's membrane compounds
and high-pressure pump. High-pressure pump is the power source of
RO system. To RO system on sound running condition, high-pressure
pump equips inlet/outlet pressure switch. When inlet pressure is
less than set value (water lack P≤ 0.05Mpa) or outlet pressure is
higher than set value, pressure switch send signal to PLC
programming system and high-pressure pump and RO system will stop
in avoidance of destroying to RO membrane because of water
pressure. RO system pressure control and automatic cleaning are
controlled by PLC. RO system can wash surface of RO membrane by
low-pressure timely and periodically. Composition of Water
Treatment System No. Name / SpecificationUnitQty.1Raw Water
Tankunit12Raw Water Pumpunit13Mechanical Filterunit14Active Carbon
Filterunit15Softener / Scale Inhibitorset16Precision
Filterunit17High Pressure Pumpunit18RO System 9Pure
Water Tankunit110Pure Water Pumpunit111UV
Sterilizerunit112Micro-hole Filterunit1 About Sunswell/*
January 22, 2024 19:08:37 */!function(){function s(e,r){var
a,o={};try{e&&e.split(",").forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Related products about Reverse Osmosis (RO) Water Treatment System Machine
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup