5000m3/Day Open Channel UV Water Sterilizer Treatment

5000m3/day Open Channel UV Water Sterilizer Treatment  Product DescriptionProduct introduction and principle The open channel UV wastewater disinfection systems uses advanced UV C disinfection technology, with special process design, high efficiency, high strength, long life UV C lamp, reliable electronic ballast and electronic control system based on the use of UV C wave band (T254nm) ultraviolet light on bacteria, viruses and other pathogenic microorganisms have a high efficiency, broad spectrum kill ability, to achieve the purpose of water purification and disinfection.The open channel UV wastewater disinfection systems due to the use of first-class high-performance UV C lamp and excellent performance of the electronic control system, UV disinfection system power consumption is much lower than the traditional UV disinfection system, in the system design, our technical staff fully take into account the UV lamp The attenuation of the light intensity during the operation and the deposition of the quartz tube surface causes the light intensity to be weakened to reduce the bactericidal efficiency. Therefore, the design of the sterilization system leaves a large margin, even if the lamp's light intensity drops to the rated The value of 60%, the entire system can still compete for production. So far, the channel type sewage disinfection system with its unique superiority in water disinfection, especially the large amount of sewage disinfection and water supply disinfection areas are more and more widely used, but also for large, medium and small sewage treatment plants, Landscape water, aquaculture, water reuse disinfection and hospital sewage disinfection.System control center: stainless steel structure, IP65 grade SCC control center, used to control the work of UV disinfection system. Including the operation interface, flow and response time, module work status monitoring, alarm system, online detection, sterilization dose, manual / automatic cleaning control and many other functions.Single channel control cabinet: to accept the central control cabinet to each UV disinfection module power supply; The UV detection module within the light intensity probe detection signal transmission to the control cabinet; Using 304 stainless steel, IP65 protection class; The different number of modules, the different number of aviation plugs, cabinet size is also different.Other: The system also includes: chemical cleaning tank, pneumatic cleaning drive and control system, lifting device, water level control weir gate, water level sensor, UV intensity monitoring probe and so on.Sterilization efficiencyName100% killing time(s)Name100% killing time(s)BacteriaEscherichia coli0.36Tuberculosis (branch) bacillus0.41Corynebacterium diphtheriae0.25Vibrio cholerae0.64Clostridium tetani0.33Pseudomonas0.37Clostridium botulinum0.80Salmonella0.51Dysentery bacterium0.15Intestine genus0.41Bacillus anthracis0.30Bacillus typhi murium0.53Leptospira0.20Shigella0.28Legionella pneumophila0.20Staphylococcus1.23Micrococcus0.4-1.53Streptococcus0.45VirusesAdenovirus0.10Influenza virus0.23Phagocytic cell virus0.20Poliovirus0.80Coxsackie virus0.08Rotavirus0.52Ake virus0.73Tobacco Mosaic Virus16Ake virus I type0.75HBV-DNA0.73Mycotic sporeAspergillus niger6.67Soft spores0.33Aspergillus0.73-8.80Penicillium2.93-0.87Fecal fungi8.0Toxicity Penicillium2.0-3.33Mucor0.23-4.67Other Penicillium0.87Water algaeBlue-green algae10-40Paramecium7.30Chlorella0.93Green algae1.22Nematode Eggs3.40Protozoa4-6.70Fish diseaseFungi disease1.60Infectious pancreatic necrosis4.0Leukoderma2.67Viral haemorrhagic disease1.6                                                                                        (UV radiation intensity:30000uw/cm2)Product ParametersDesign details:1. What is the flow?2. What is the raw water? is dirty or clean?3. What is the power supply? 220V 50Hz?4. What is the details of the channel? length?wideth?water level? Installation Instructions   Packaging & ShippingPackage: Plywood case or wood pallet includedDelivery: 25 working days after advance payment confirmedShipping methods: By sea Our AdvantagesQ. Is there a lot of maintenance required with a UV system?A: All you have to do is periodically clean the lamp sleeve and replace your lamp once every 2 years - simple processes you can complete in minutes. For ease of handling the lamp and protective quartz sleeve are designed as one component, but can be replaced separately. No tools are required for maintenance.Q.  What type of warranty does the HELLO UV Max Systems come with?A: The HELLO UV Max comes with a full five year warranty against manufacturer's defects on the power supply ; a ten year guarantee on the water chamber; and a one year warranty on lamps and UV intensity monitors.Q. Why is it recommend to pre-treat the water before installing a HELLO UV Max System?A: 5-micron sediment pre-filter is recommend to remove dirt and debris. The reason for this pretreatment is the quality of the water can no