Marya Top Seller Heat Recovery Ahu for Wide Range of
Applications Product Description The cleanroom AHU
realizes the functions of refrigeration, heating, dehumidifying,
heating, humidification, purification and sterilization through a
variety of heat and humidity treatment schemes and air purification
treatment, so as to achieve precise control of the indoor
environment temperature, humidity, and cleanliness. Main
PerformancesThe air volume of the combined AHU ranges from 3500m³/h
to 200,000m³/h for users to choose and combine freely. It is mainly
suitable for the air purification system of various clean
workshops. Such as industrial electronics factory, precision
machinery manufacturing factory, textile workshop, automobile
spraying workshop, GMP pharmaceutical factory, cosmetics, food
factory, pure water workshop, hospital operation department, ICU
and other occasions.According to the structure type, it can be
divided into horizontal, vertical and ceiling type; according to
the characteristics of use, it can be divided into general unit,
fresh air unit, purification unit and special unit (such as roof
unit, subway unit and computer room special unit, etc. ); it can
also be classified according to specifications, the basic
specifications of the unit can be expressed by the rated air
volume.The basic principle of setting the functional section of the
purification unit is determined according to the production process
or cleanroom requirements; the combination and selection of the
functional section of the purification unit should be closely
integrated with the design of the air-conditioning room, and the
microbial contamination points in the purification unit must be
controlled. Because the structure, temperature and humidity are
more suitable for the growth of bacteria and other microorganisms,
the cabinet, filter, muffler, humidifier, etc. of the purification
unit have become potential microbial contamination place, which
must be controlled. If the unit box is free from damage and
corrosion, disinfection resistance, heat preservation and sealing
performance, we can use antibacterial materials that have been
widely used in refrigerators; filter performance indicators meet
the requirements; mufflers, humidifiers, etc., do not retain
materials. The functional segments of the air conditioning unit are
as follows:New return air mixing section; the new return air
opening position can be set at the end, top or left and right sides
according to the design requirements, and specific opening
positions should be provided for special requirements. A regulating
valve can be installed on the new air return port. The actuator has
three types of manual, electric and pneumatic, which can be
selected by the user.The filter section has two kinds of primary
and medium-efficiency filtration. It is equipped with a diamond bag
type, a four-peak bag type, and an automatic winding type. The
filter material is made of high-quality polyester non-woven fabric,
and the filter is quickly assembled and disassembled, gland display
and alarm deviceThe new exhaust section (also known as the flat
air-distribution mixing section) is equipped with a primary air
return valve in the box. The top of the box before and after the
valve is equipped with an exhaust outlet and a new air outlet, and
is equipped with a regulating valve. Its function is: When there is
a return fan, supply the air conditioner to discharge part of the
return air, so that the fresh air and the primary return air are
mixed according to the required ratio; when the direct current
system is adopted in the transition season, the primary return air
valve should be closed, and the exhaust valve and fresh air valve
should be fully opened.The energy recovery section is used for
cross-air mixing and exhaust air energy recovery in the dual fan
system. This section of the box is equipped with a primary air
return valve, and the top is an energy recovery device. It uses the
cold (heat) of the exhaust air to indirectly cool (heat) the fresh
air. The fresh air passes through the plate energy recovery device
to recover about 60% of the sensible heat energy of the exhaust
air. At the same time, the exhaust air and the fresh air are not
direct contact, which is especially suitable for energy recovery of
the DC air-conditioning system that eliminates harmful indoor
gases. When used as a DC system, the return air valve should be
closed once. Places with highly toxic gases should have a separate
exhaust system.Intermediate section (maintenance section) This
section is used for the connection of the transition section and
the internal maintenance lighting of the unit. Before the filtering
section, there must be an intermediate section before and after the
surface cooling section, heating section, and muffler section.The
middle section of the second air return pipe of the secondary air
return section, the top can be equipped with an adjustable valve,
and it is equipped with manual, electric o
Related products about Marya Top Seller Heat Recovery Ahu for Wide Range of Applications
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup