evaporative with capacity 2010kw ZHX-2010Technical
Data: MODELCAPACITYNOMINAL FAN PUMPInlet/OutletDN(mm)DIMENSION(mm) LengthWidthHeight Can.(set)Motor(kw/set)Volumen(m3/h)Can.(set)Motor(kw/set)Volumen(m3/h) ZHX-20102010KW4445,00015.52302-DN125745022004720
Notes: Design condition: wet bulb temperature 28.2ºC, inlett water
temperature 37ºC, outlet water temperature 32ºC. Working
principleFor ZHX combined flow evaporative condenser, the coil will
soaked fully by spraying water when the process fluid flows inside,
meanwhile, the heat of working fluid will be transferred by wall of
coil tube, and become saturated wet-hot vapor after mixed with
water and air, then it will be discharged into atmosphere by fan,
but water will be collected into water collection basin by drift
eliminator for recycled spraying, low water consumption. The
spraying water temperature will be reduced by PVC infill during the
recycling, and it flows in same direction to fresh air, and to cool
the coil mainly by sensible heat conduction
way. Advantage:Δ Excellent Heat Exchange
PerformanceThe serie ZHX production use the technical the
combination of coils and PVC fill, which coil has heat exchange
secondary with the same path of air and water, this effectively
avoid the dry spot and scale formation, and improve the heat
exchange performance.Δ Convenient MaintenanceHuge maintenance
space makes it convenient to inspect the product. Technicians can
enter the cooling tower during operation time.Realize non-stop
maintenance.Δ Convenient Transportation and InstallationThe
Evaporative condenser is designed to be standard upper body part
and bottom body part, making it is able to be shipped separately
and saves transportation and installation cost.Δ Slope Water
Basin DesignThe design that the bottom of the sump is inclined to
the end of the wastewater outlet and the design that the heat
exchange layer of the PVC fill is suspended facilitate cleaning and
the escape of dirty water and impurities.Main
Components: Application
Samples: 1. Water-source Heat
Pumps 2. Self-contained Cooling
units 3. Data centers, computer room air
conditioning system 4. Hybrid evaporative/
Dry cooling 5. Cooling special fluids:
hydraulic oil, electroplating
solution, quenching
oil,circulating water production 6. Compress
jacket cooling,cooling inter
cooling 7. Induction furnace of steel
plant and jobbing
foundries, cooling rolling
machine,the quenching tank, continuous
casting 8. Consolidating multiple,loads into
a single cooling unit 9. Intermediate
frequency furnace10. Injection
mold,transformer11. Power plants,paper mills,food
factory Packaging & Shipping1) Standardized
modular design, two body parts: upper body part and bottom body
part;2) Shipped by one 20ft/40ft container,upper and bottom body
parts shipped assembly and separately;3) Bottom body parts, will
packed with plastic film to anti moisture, shipped
assembly; 4) Upper body parts, will packed with plastic film
to anti moisture, shipped assembly. Our ServicesPre-Sale
Service* Professional Technical and Sales Service Team* Techncial
Proposal, CAD Drawings available * Welcome to View Our
Factory.After-Sale Service* Training how to install, operate, and
maintaining the equipment. * Engineers available to service
machinery overseas. Company InformationHeng An Cooling is
a professional heat exchanger equipment supplier, products
range radiators, cooling tower, evaporative condenser, and air
cooled heat exchanger.Established in 1975, we have been engaged to
provide best solution and quality equipment to the customers. With
a good reputation of reliable and durable performance, Heng An
products hot sell in market over 30 countries worldwide.Welcome to
visit our factory, and looking forward to the cooperation with
you. FAQ(1)Your company is a manufacture or
trading company?We are a leading cooling tower manufacturer
with 38 years producing experience. The famous brand-"Heng An" is
well known not only China but all over the world. The company is
a large group company loacted in Weifang Citey of China.(2)
What is the difference between a "counter flow" and
a "cross flow" cooling tower?The crossflow or counterflow
designation characterizes the orientation of the airflow within the
heat-transfer media (fill) in the tower with respect to the
direction of water flow.In counterflow towers air travels
vertically upwards through the fill and makes intimate contact with
water droplets falling down through the fill media. Hence the air
and water travel in opposite directions.In crossflow cooling towers
the air passes through the fill media in a horizontal
direction, thus crossing the downward water flow. Counterflow
towers are inherently more efficient than crossflow towers.(3) What
is your Minimum Order Quantity(MOQ)? MOQ is
1set. Because our business for both wholesale and retail
clients.(4) How do I get re
Related products about R22 R134A Combined Flow Evaporative Condenser for Chemical Plant Factory
- Waste Tyre Plastic Recycling Machinery Machine Tire Crusher Production Line Rubber Crumb Grinding Machine Equipment Tire Shredder
- Stretch Plastic Blowing Pet Bottle Making Blow Molding Machine Bottles Stretch Automatic Pet Bottle Blowing Machine
- Waste Plastic Pet Bottle, Water Bottle Flake, PP/HDPE/LDPE PE Film Jumbo Woven Bags Plastic Crusher Machine, Plastic Crushing Washing Recycling Machine
- Type 2 Wall-Mounted Electric Car Charging Station 7kw /11 Kwelectric Vehicle Charging Station Home Wallbox AC EV Charger Single Phase or 3three Phase
- G-View G12W Wholesale Auto Car LED Headlight Bulb High Power H13 H11 9005 H7 H4 Car LED Headlights LED Car Lights
- New Design Porcelain Round Plates Dinner Set for Wedding and Banquet
- China 2023 New Design Super Soft 100% Polyester Microfiber Knitted Oversized Decoration Hoodie Blanket
- Handmade Art Creative Materials Thickened White Paper Cup DIY Disposable Handmade Colored Paper Cup