Central Air Conditioner Chilled Water Cassette Fan Coil Unit

Central Air Conditioner Chilled Water Cassette Fan Coil Unit1.Ceiling cassette fan coil brief introductionThe water cassette fan coils are able to meet the several and different requirements of air conditioning and heating market. Intended for ceiling and false ceiling installation. Cassette fan coil is widely applied in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place, etc.Product TypeCeiling Cassette Fan Coil UnitMotorAC (DC as optional)Air Outlet4 way air discharge (1 way,,360 angle degrees optional )Pipe System2 pipes or 4 pipes Cooling Capacity2KW ~ 15KW (2 pipe system)Heating Capacity3.1KW ~ 24KW (2 pipe system)Cooling Capacity1.95KW ~ 13.2KW (4 pipe system)Heating Capacity1.95KW ~ 13.5W (4 pipe system)2. Ceiling cassette fan coil unit main componentsFanCentrifugal type, pass statically and dynamically balanced testMotorSingle-phase motors are suitable for different voltages, DC optionDrain pumpHigh lift water drained pump drains out the condensate water CoilHydrophilic blue aluminium fin around with copper tubeCasingGalvanized steel casing for master unit; ABS cover panel3. Ceiling cassette fan coil features(1) Strong constructure:The unit's bearing structure is made from galvanised steel sheet, externally and internally insulated with heat and soundproofing material.(2)Elegant designed panel: Air intake and outlet polystyrene panel, preformed high density polystyrene foam air passages complete with air suction grid, a washable polypropylene filter and adjustable air outlet fins.(3)Low noise fan:Centrifugal fan with backward-curving blades. The blades are designed for very low-noise and efficient operation also at slow speed, plastic blade is optional.(4)High efficient motor: Single-phase motors are designed for long life.(5)High efficient heat exchanger: made with copper piping and aluminium fins.(6)Safety running: Condensate drainage pump complete with float and a level switch.(7)Convenient maintenace: panel can be easily open and filter is easily taken out and washable.(8)Divers Controller: infrared remote controller or wired controller  4. Eurostars Fan coil unit series1Ceiling concealed fan coil unit2High ESP ducted fan coil unit3Universal concealed fan coil unit4Floor standing exposed fan coil unit5Ultra thin exposed fan coil unit6Ceiling exposed fan coil unit7Ceiling cassette fan coil unit8Ceiling exposed & floor standing fan coil unit9Wall mounted fan coil unit5. Ceiling cassette fan coil unit specificationPlease ask salesman for detailed complete data or visit our website:eurostarschiller.en.made-in-china.comeurostarschiller.en.made-in-china.comCassette Fan Coil Unit (4-way  2 pipe system)Model   EST~200C2300C2400C2500C2600C2800C21000C21200C21400C21600C2Power supply220V-1PH-50/60HZAir flow (m3/h)H360540720900108014301780213024801830M29039052567077510501290156018102050L190270350440540720870106012901370Static pressurePa0000000000Cooling capacityTHHW2000300038004900580075009800110001200015000BTU/h6826 10239 12969 16724 19795 25598 33447 37543 40956 51195 SHW14002200285035004250550071508250910011175BTU/h4778 7509 9727 11946 14505 18772 24403 28157 31058 38140 THMW170025503250415049506400835093501020012450BTU/h5802 8703 11092 14164 16894 21843 28499 31912 34813 42492 SHW1150180023502850350045505950685076509560BTU/h3925 6143 8021 9727 11946 15529 20307 23379 26109 32628 THLW14002050260034004000520067507600830010300BTU/h4778 6997 8874 11604 13652 17748 23038 25939 28328 35154 SHW950140018502300280036004700545060008400BTU/h3242 4778 6314 7850 9556 12287 16041 18601 20478 28669 Heating capacityHW310047005900760090001160015200171001860024000BTU/h10580 16041 20137 25939 30717 39591 51878 58362 63482 81912 MW26504000500064507650985012900145501580019900BTU/h9044 13652 17065 22014 26109 12900 44028 49659 53925 67919 LW21003150395051006050775010200114501245015200BTU/h7167 10751 13481 17406 20649 26451 34813 39079 42492 51878 Cassette Fan Coil Unit(4-way  4 pipe system) Model   EST~200C4300C4400C4500C4600C4800C41000C41200C41400C41600C4Power supply220V-1PH-50/60HZAir flow (m3/h)H340510680850102013601700204023802720M28038051566076510401280155018002040L180260340430530710860105012801360Pressure Pa0000000000Cooling capacityTHHW1950295037004800570073509600108001175013200BTU/h6655 10068 12628 16382 19454 25086 32765 36860 40103 45052 SHW13502150280034504150540070008100890010000BTU/h4608 7338 9556 11775 14164 18430 23891 27645 30376 34130 THMW165025003200405048506250820091501000011000BTU/h5631 8533 10922 13823 16553 21331 27987 31229 34130 37543 SHW11501750230028003450445058506700750037532BTU/h3925 5973 7850 9556 11775 15188 19966 22867 25598 128097 THLW1350200025503350390051006600745081509100BTU/h4608 6826 8703 11434 13311 17406 22526 25427 27816 31058 SHW950135018002250275035504600535059006600BTU/h3242 4608 6143 7679 9386 12116 15700 18260 20137 22526 Heating capacityHW1950300037504850575074009700109001185013500BTU/h6655 10239 12799 16553 19625 25256 33106 37202 40444 4