House Heating Air Source Heat Pump Water Heater

1.Application of Air Source Heat PumpEVI air source heat pump (for DHW and/or house heating) is designed for domestic hot water and/or house heating, with 3-way valve, heat pump controller can change the circulating direction of water between hot water tank and house heating system, and hot water is priority.2.Eurostars Air Source Heat Pump Features:EVI air source heat pumps are designed for domestic/commercial hot water and house heating in cold areas where lowest air temperature is above -25ºC,They are featured with: --- Efficient and Energy-saving Air to water heat pumps absorb hot energy from the air freely, while the electricity is only used to drive the compressor to pump up the heat from the air, so they consume just a quarter of power of traditional electric water heaters, saving a lot of electric cost for users.  ---Green and Environmental ProtectionBy using air source energy and electric power, there is no harmful gas being discharged during the operation of heat pumps. R410A and R407C refrigerant guarantees fluoride-free emission. ---All-weather OperationStable operation without being influenced by windy, rainy or snowy weather. ---Endurable The Enhanced Vapor Injection (EVI) technology from Copeland compressor with crankcase heater for special cold area, famous brand electronic expansion valve, Eaton/ Schneider/FUJI AC contactor and thermal relay as well as other brand components of the heat pump guarantee high product quality and a long lifespan. All of our screws and clips (both external and internal) are rust resistant , stainless steel is optional. The cabinet we are using is made of galvanized steel, making the product more rust resistant and durable.---Multiple ProtectionsEurostars heat pumps with multiple protections: For example, if water flow is not enough in the system, the system will show high pressure protection and stop the heat pump automatically to protect the compressor from being damaged. Also, there is high current protection: if the power supply is not stable, the heat pump will show the high current error to stop the heat pump and avoid compressor damage.---Guaranteed SafetyComplete isolation of water and electricity avoids electric shock, explosion and poisoning. ---Convenient: EVI heat pumps are easy to install. They can be placed in many places, such as garages, balconies, kitchens, etc. 3. Air Source Heat Pump Technical DataAir Source Heat Pump Unit(EVI Low Ambient Temp.Type) (Heating Only)ModelESSA-05LHNESSA-05LHNESSA-05LHNESSA-05LHN2.5ES3ES4.5ES5ESWorking modeHeatingPower supply220V/50HZ380V/50HZ220V/50HZ380V/50HZAir DB/WB: 7ºC/6ºC,water In/outlet:40ºC/45Heating capacity (kW) 7.68.414.015.2Input power(kW) 2.322.584.384.75Current(A) 11.14.721.08.7COP(W/W)3.283.263.203.20Water flow(m3/h)1.71.93.13.4Air: -10ºC/ ,Water In/outlet:40ºC/45Heating capacity (kW) 5.325.889.810.64Input power(kW) 2.202.454.164.51COP(W/W)2.412.402.362.36Air: -20ºC/   ,Water In/outlet:40ºC/45Heating capacity (kW) 4.04.47.48.0Input power(kW) 2.092.333.954.29COP(W/W)1.911.891.861.86Air: -25ºC/ ,  Water In/outlet: 40ºC/45Heating capacity (kW) 3.94.26.47Input power(kW) 2.352.523.964.30COP(W/W)1.661.671.621.63 ModelESSA-10LHNESSA-10LHNESSA-10LHNESSA-15LHN5.5ES7ES2*5ES2*7ESWorking modeHeatingPower supply220V/50HZ380V/50HZ380V/50HZ380V/50HZAir DB/WB: 7ºC/6ºC,water In/outlet:40ºC/45Heating capacity (kW) 17.519.030.440.8Input power(kW) 5.465.949.512.75Current(A) 26.110.817.323.2COP(W/W)3.23.23.23.2Water flow(m3/h)3.94.26.89.1Air: -10ºC/ ,Water In/outlet:40ºC/45Heating capacity (kW) 12.2513.321.2828.56Input power(kW) 5.195.649.0312.11COP(W/W)2.362.362.362.36Air: -20ºC/   ,Water In/outlet:40ºC/45Heating capacity (kW) 9.210.016.021.4Input power(kW) 4.935.368.5711.51COP(W/W)1.861.861.861.86Air: -25ºC/ ,  Water In/outlet: 40ºC/45Heating capacity (kW) 7.591419Input power(kW) 5.105.808.6012.00COP(W/W)1.471.551.631.58 ModelESSA-20LHNESSA-30LHNESSA-40LHN 4*5ES4*7ES4*9ES Working modeHeatingPower supply380V/50HZ380V/50HZ380V/50HZ Air DB/WB: 7ºC/6ºC,water In/outlet:40ºC/45Heating capacity (kW) 60.076.0115 Input power(kW) 18.7023.7635.90 Current(A) 34.143.365.5 COP(W/W)3.213.203.20 Water flow(m3/h)13.417.025.7 Air: -10ºC/ ,Water In/outlet:40ºC/45Heating capacity (kW) 42.0053.2080.50 Input power(kW) 17.7722.5734.11 COP(W/W)2.362.362.36 Air: -20ºC/   ,Water In/outlet:40ºC/45Heating capacity (kW) 31.539.960.4 Input power(kW) 16.8821.4432.40 COP(W/W)1.871.861.86 Air: -25ºC/ ,  Water In/outlet: 40ºC/45Heating capacity (kW) 28.0038.00  Input power(kW) 17.2024.00  COP(W/W)1.631.58  4.Air Source Heat Pump Main Components Introduction1)Copeland Compressor :High quality Scroll Compressor .2)Fan: Well selected axial fan motor combined with large fan blade, which provide heavy air blow at low rotate speed, reducing vibration and noise.3)Expansion Valve: SANHUA/Danfoss Expansion valve, with more precise control of refrigerant flow system, which optimize heat pump working capacity and efficiency under different ambient conditions.4)Hi