Packaged Copeland Scroll Compressor Air Cooled Water Industrial Chillers

Packaged Copeland Scroll Compressor Air Cooled Water Industrial Chillers1. Eurostars air cooled water chiller main componentsHermetic CompressorIndustry leader, long lasting compressor with motor contactorMicroprocessor ControlStand alone,simple, accurate control with over 10 years field testingStainless Steel Brazed Plate EvaporatorCorrosion resistant evaporator wrapped in closed cell insulation Copper Tube/Aluminum Fin CondenserRust resistant and high CFMStainless Steel PumpFused, non-ferrous pump for process circulationPolyethylene Storage Tank Closed cell insulation for increase temperature control with reliable, corrosion resistantPainted Galvanized Steel Metal CabinetSturdy, corrosion resistance, professional appearanceInsulated Process Fluid Lines Maximum thermal efficiencyFactory Tested Ensures the unit meets the customer's performance designed criteria and arrives in working orderFull Refrigerant ChargeHassle free and more efficient installation2. Air cooled industrial chiller applicationsEurostars industrial chillers are depended upon to serve the process cooling needs of a wide variety of industries, and are selected due to their advanced designs which are focused on energy efficiency, reduction of water consumption, reduced maintenance, and improved reliability of both the cooling system and the processes and equipment it serves. It is widely used for the following industry:injection industrypackaging industrywelding industryvacuum coatingNC industryprinting industrymedical industrylaser industry3. Air cooled chiller VS Water cooled chiller(1)Air cooled chillers require less maintenance than water-cooled units.(2)Air cooled chillers do not require a cooling tower or a condenser water pump.(3)Air cooled chillers outdoors installation, save installation space.4. Eurostars air cooled industrial chiller brief technical data Please ask salesman for detailed complete data or visit our website:eurostarschiller.en.made-in-china.comeurostarschiller.en.made-in-china.comAir Cooled Chiller UnitModel      ESSA-01ISSN02ISSN03ISTN04ISTN05ISTN06ISTN08IDTN10IDTN12IDTNItem NO.12345681012Rated Cooling CapacityKW2.76 5.72 8.96 11.31 14.12 17.24 22.62 28.24 34.48 USRT0.78 1.63 2.55 3.22 4.02 4.90 6.43 8.03 9.81 ×1000 kcal/h2.37 4.92 7.71 9.73 12.14 14.83 19.45 24.29 29.65 Air Cooled Chiller UnitModel      ESSA-15IDTN20IDTN25IDTN30IDTN40IQTN50IQTN60IQTNItem NO.15202530405060Rated Cooling CapacityKW43.2258.271.1887.387.78116.4142.36177.95175.56USRT12.29 16.55 20.24 24.83 24.97 33.11 40.49 50.61 49.93 ×1000 kcal/h37.17 50.05 61.21 75.08 75.49 100.10 122.43 153.04 150.98  Remarks:(1) Rated Cooling Capacity Based on:Evaporating temperature 7ºC;Condensing temperature 50ºC,Ambient DB=35ºC.(2)Chilled Water Range: 5~25ºC;5.Factory testing of Eurostars every chiller unit(1)Pressurization and helium leak detection of refrigeration circuit(2)Pressurization and leak testing of fluid circuit(3)Chiller performance and power consumption at full load(4)Proper operation of all controls, safety devices, and alarms(5)Electrical tests according to standards   6. How to correctly size a chiller?Simple instructions to assure proper cooling for your Industrial applicationThe importance of selecting a correctly sized chiller is crucial. An undersized chiller will always be a problem-never able to properly cool the process equipment. An oversized chiller will never be able to run at it's most efficient level. Identify the correct size chiller and rely on years of continuous, efficient cooling for your application. If you would like help, feel free to give us a call. To give you an idea of how to correctly size and select the best solution for your application, please use the formula below.(1)Calculate the "delta T", the change in temperature, between the inlet and outlet water. Measuring the "delta T" requires a thermocouple or thermometer. Check the water temperature of the water inlet line and the water outlet line, and subtract the numbers to compute how much heat the equipment is adding to the water.(2)Rate of flow in gallons per minute (GPM). To measure the flow rate of the water place a flow meter on the outlet line of your equipment. If one is not available, simply measure the time it takes for the outlet flow to fill a five gallon bucket, and then compute your gallons per minute (GPM) of flow.Now that you have these two figures, calculate how many BTU's (British Thermal Units) your equipment puts off.BTU/ hour = 500 x GPM x Temperature Difference (delta T)Repeat this for all the equipment you have, and add up the total BTUs. Now that you have the BTUs, compute the total tons of cooling you need from a chiller. For example, 1 Ton of cooling is 12,000 BTU/hour s# Tons = (BTU/hr) / (12,000)This is the size unit you should need. There may be other circumstances, like planning for expansion, that would lead you to buy a different size unit.7. Eurostars Company Ceritifcate & Customer VisitingWe, EUROSTARS, which established in year 2006, i