Fan Filter Unit ULPA/HEPA Filter Laminar Flow Hood for Class 100 / ISO 5 Cleanliness Clean Room

Fan Filter Unit ULPA/HEPA Filter Laminar Flow Hood for Class 100 / ISO 5 Cleanliness Clean RoomPRODUCT SPECIFICATIONModeSL-30CDCZPN1SL-15CDCZPN1Exterior size1174mmx1174mmx300mm574mmx1174mmx265mmFilter size1170mm x1170 mmx70 mm570mm x1170mm x70 mmFilter efficiencyHEPA/ULPAHEPA/ULPAAverage air speed0.45m/s±10%0.45m/s±10%Motor brandTaiwan DEI/ZhongweiTaiwan DEI/ZhongweiMotor type Brushless DC Permanent Magnet Motor Brushless DC Permanent Magnet MotorMotor efficiency≥88%≥88%Noise0.25-0.45/sec,48-55d BA0.25-0.45/sec,48-55d BANoise test1.5M under filter screen1.5M under filter screenPowerAC 1Ph , 200 ~ 240 , 50/60HzAC 1Ph , 200 ~ 240 , 50/60HzBox materialAluminium-Zinc alloy coated steel/Stainless SteelAluminium-Zinc alloy coated steel/Stainless SteelBox material thicknessOuter box≥0.8mm, Base≥2.0mmOuter box≥0.8mm, Base≥2.0mmBox structureFull disassembly simple maintenance(Fan, Motor, Controller)Full disassembly simple maintenance(Fan, Motor, Controller)NoteSpecial specification can be customized.   PRODUCT DISCRIPTIONSSnyli Fan Filter Units (FFU) are the most energy efficient line of fan filter units on the market today. Designed specifically for use in cleanrooms, pharmacies, pharmaceutical manufacturing facilities and laboratories, the FFU delivers high volumes of HEPA (or ULPA) filtered air at low sound levels while reducing energy consumption by 15 to 50% versus comparable products becuase of it's equipment of Brushless DC Permanent Magnet Motor design.PRODUCT FEATURES*Industry leading Brushless DC permanent magnet motor,sine wave  vector control technology. * Zero speed start full closed-loop control, no risk of open-loop closed-   loop switching failure.* Small starting current, smooth acceleration and deceleration, no   motor demagnetization risk.* Perfect sine wave operation, low loss, low noise, small vibration.* Powerful motor torque control function, high speed accuracy,    startsmoothly in case of 400 RPM against the wind.* Complete abnormal protection of over-voltage, over-current,short  circuit, open circuit, over temperature,etc.* Meet the requirements of EMC and electrical safety certification.* Low standby power consumption (< 1.2W) and high overall efficiency.* Integrated PFC function to achieve higher power factor and lower   harmonic current.* The key components adopt foreign famous brand products to ensure   high performance and high reliability.   FFU GROUP CONTROL SYSTEM--FFU group control system structure5DT can be monitored by 1Gateway,1 host DT control master can be connected with Maximum 63 FFU .* 1 Central host computer (PC) (Note: Ethernet switch HUB   is selected according to the actual quantity.* Gateway:Modbus-RS485 TCP.* Data Collector (DT): Standard protocol Modbus-RS485 --Simple operation* FFU software graphic interface control , easy to operate and expand .* Through the color of FFU fan button in the interface page, the different operation states of FFU can be identified,   which is intuitive and eye-catching.--Scientific early warning system,much safer* When the alarm occurs, there is a certain ratio of color change.* The different operation states of FFU can be identified  by the color of FFU fan button in the operation interface,which   is intuitive and eye-catching.--Inintelligent monitoring* Complete, secure and open network system, intimely and best monitoring and control.* It can be monitored and controlled independently by regional or single FFU.* After FFU is powered off, it will operate according to the state (power supply,wind speed) before the last shutdown when  power is on again.* Software intelligent scheduling management, FFU Timing set is available,energy saving.* FFU control box also equiped with field LED indicator light showing running status.* FFU automatic grouping order delay start, avoiding the impact of starting current on user's power system in large-scale system.* It can be connected with tempreture/humidity sensor, the fan speed can be automatically adjusted withthe change of pressure  difference.FILTER AND FFU PARAMETER CURVE Q1.Are you a manufacture or trading company?A:We are a manufacure.Snyli Environmental Technology (Shandong) Co., Ltd was established in 2010, is a professional service provider of air purification products integrating R&D, production and sales, with registered brand- SYNLI.Q2: Where are air filters commonly used?A :HAVC(heating, air conditioning and ventilation systems) painting stations, chemical plants, pharmaceutical plants, cement or asphalt powder plants, clean rooms, power stations, heavy metal industries, gas turbines and cogeneration power plants, engineering and equipment plants, drying and baking rooms, hospitals, etc.Q3: What are your testing criteria?A: EN779:2012 ISO9001Q4: What is the international standard for air filters?A:Euro :Pre (G1-G4), Medium (F5-F9), HEPA (H10-H14) ULPA (U15-U17)American :Pre (MERV5-7), Medium (MERV8-14), HEPA (MERV15-19) ULPA(MERV 20)Q5: What is your sample policy?A: The sample price wi