P18-6 (Skid) Soundproof Generator Set Silent Welding Diesel Power Generators

Product DescriptionWilson Advantage1.Product advantages*Start-up performance: It takes 5 seconds to reach a stable state after starting the cranking, and it takes about 15 seconds to reach full load.*Loading capacity: One-step loading capacity exceeds 50%*Power density:High power density, small unit size*Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section*Extended warranty service:60-month extended warranty service2.service advantage*Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs.*Advanced control and parallel system*Remote cooling device*Emission silencer system*Rainproof and anti-speaker box*High insulation level*Customized testing 3. Complete solution-pre-sales support:*Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy;*Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc.4. Complete solution-after-sales support*Provide professional product training*FG Wilson Original Parts Consulting Help*Ensure timely supply and delivery of parts*Complete warranty, extended warranty and customer service agreementsProduct certification and qualificationsP18-6 model product detailsRatings and Performance DataEngine Make PerkinsEngine Model: 404D-22G1Alternator Make FG WilsonAlternator Model: FGL10040Control Panel: FG100Base Frame: Heavy Duty Fabricated SteelCircuit Breaker Type: 3 Pole MCBFrequency: 50 HZ60 HZEngine Speed: RPMrpm15001800Fuel Tank Capacity:litres (USgal) Fuel Consumption Primelitres (USgal)/hr4.4 (1.2)5.3 (1.4)Fuel Consumption Standbylitres (USgal)/hr4.8 (1.3)5.8 (1.5)  Engine Technical DataNo. of CylindersAlignmentCycleBoreStrokeInductionCooling MethodGoverning TypeGoverning ClassCompression RatioDisplacementMoment of Inertia:VoltageGroundBattery Charger AmpsEngine Weight DryEngine Weight Wetmm (in)mm (in)L (cu. in)kg m² (lb/in²)kg (lb)kg (lb)4IN LINE4 STROKE84 (3.3)100 (3.9)NATURALLY ASPIRATEDWATERMECHANICALISO 852823.3:12.2 (135.2)2.724 (9308)12Negative65242 (534)251 (554)Engine Performance Data50 Hz60 HzEngine Speedrpm15001800Gross Engine Power PrimekW (hp)16.2 (22)19.4 (26)Gross Engine Power StandbykW (hp)18 (24)21.5 (29)BMEP PrimekPa (psi)585 (84.8)583 (84.6)BMEP StandbykPa (psi)649 (94.2)647 (93.8)Fuel SystemFuel Filter Type:  Replaceable ElementRecommended Fuel: Class A2 DieselFuel Consumption at 110 % Load100 % Load75 % Load50 % Load50 Hz Prime:l/hr (USgal/hr)4.8 (1.3)4.4 (1.2)3.4 (0.9)2.6 (0.7)50 Hz Standbyl/hr (USgal/hr)-4.8 (1.3)3.7 (1)2.7 (0.7)60 Hz Primel/hr (USgal/hr)5.8 (1.5)5.3 (1.4)4.1 (1.1)3.2 (0.8)60 Hz Standbyl/hr (USgal/hr)-5.8 (1.5)4.5 (1.2)3.3 (0.9)  Air System50 Hz60 HzAir Filter Type: Replaceable ElementCombustion Air Flow PrimeCombustion Air Flow StandbyMax. Combustion Air Intake Restrictionm³/min (cfm)m³/min (cfm)kPa1.5 (51)1.5 (51) 3 (12)1.7 (61)1.7 (61) 3 (12)  Cooling System50 Hz60 HzCooling System Capacityl (USgal)6.5 (1.7)6.5 (1.7)Water Pump Type: CentrifugalHeat Rejected to Water & Lube Oil: PrimekW (Btu/min)13.7 (779)                                               15.5 (881)Heat Rejected to Water & Lube Oil: StandbykW (Btu/min)15.2 (864)                                               17.2 (978)Heat Radiation to Room*: PrimekW (Btu/min)5 (284)5.7 (324)Heat Radiation to Room*: StandbykW (Btu/min)5.8 (330)6.3 (185)Radiator Fan Load:kW (hp)0.2 (0.3)0.4 (0.5)Radiator Cooling Airflow:m³/min (cfm)33 (1165)41.4 (1462)External Restriction to Cooling Airflow:Pa (in H2O)125 (0.5)125 (0.5)*: Heat radiated from engine and alternatorDesigned to operate in ambient conditions up to 50°C (122°F).Contact your local FG Wilson Dealer for power ratings at specific site conditions.  Lubrication SystemOil Filter Type: Spin-on, Full flowTotal Oil Capacity:Oil Pan Capacity:Oil Type:l (USgal)l (USgal)10.6 (2.8)8.9 (2.4)API CH4 15W-40Oil Cooling Method: N/A  Exhaust System 50 Hz60 HzMaximum Allowable Back Pressure:kPa (inHg)10.2 (3)10.2 (3)Exhaust Gas Flow: Primem³/min (cfm)3 (105)3.9 (138)Exhaust Gas Flow: Standbym³/min (cfm)3.2 (114)4.3 (151)Exhaust Gas Temperature: Prime°C (°F)364 (687)396 (745)Exhaust Gas Temperature: Standby°C (°F)413 (776)459 (858)  Alternator Physical DataNo. of Bearings:1Insulation Class:Winding Pitch:Winding CodeWires:Ingress Protection Rating:Excitation System:AVR Model:H2/36S/6P4IP23SHUNTR120* dependant on voltage code selectedAlternator Operating DataOverspeed: rpm2250Voltage Regulation: (Steady state) Wave Form NEMA = TIF:Wave Form IEC = THF:Total Harmoni